CVE-2026-35548

HighCVSS 8.5/10Last modified Jun 17, 2026

Description

An issue was discovered in guardsix (formerly Logpoint) ODBC Enrichment Plugins before 5.2.1 (5.2.1 is used in guardsix 7.9.0.0). A logic flaw allowed stored database credentials to be reused after modification of the target Host, IP address, or Port. When editing an existing Enrichment Source, previously stored credentials were retained even if the connection endpoint was changed. An authenticated Operator user could redirect the database connection to unintended internal systems, resulting in SSRF and potential misuse of valid stored credentials.

Metrics

CVSS 3.1 8.5/10CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:L/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 22, 2026
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2026

CVE-2026-355496.5An issue was discovered in MariaDB Server before 11.4.10, 11.5.x through 11.8.x before 11.8.6, and 12.x before 12.2.2. If the caching_sha2_pCVE-2026-35558.0Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability alCVE-2026-355528.1In CAXperts UPVWebServices 2.4.2212.603 through 2.7.6 and UDiTH Portal 2026.0.0 through 2026.2.0, an authenticated remote user can invoke anCVE-2026-355536.7Bluetooth ACPI Drivers provided by Dynabook Inc. contain a stack-based buffer overflow vulnerability. An attacker may execute arbitrary codeCVE-2026-355548.7A race condition in the Apache Kafka Java producer client’s buffer pool management can cause messages to be silently delivered to incorrect CVE-2026-355556.3PowerSYSTEM Center feature for device project groups allows an authenticated user with limited permissions to perform an unauthorized deletiCVE-2026-355567.5OpenPLC_V3 is vulnerable to a Plaintext Storage of a Password vulnerability that could allow an attacker to retrieve credentials and access CVE-2026-355587.8Improper neutralization of special elements in the authentication components in Amazon Athena ODBC driver before 2.1.0.0 might allow a threaCVE-2026-355596.5Out-of-bounds write in the query processing components in Amazon Athena ODBC driver before 2.1.0.0 might allow a threat actor to crash the dCVE-2026-35568.8Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjaCVE-2026-355605.9Improper certificate validation in the identity provider connection components in Amazon Athena ODBC driver before 2.1.0.0 might allow a manCVE-2026-355619.8Insufficient authentication security controls in the browser-based authentication components in Amazon Athena ODBC driver before 2.1.0.0 mig
CVE-2026-35548: High severity, CVSS 8.5 | Vulnix