Description
In the Linux kernel, the following vulnerability has been resolved:
mmc: vub300: fix NULL-deref on disconnect
Make sure to deregister the controller before dropping the reference to the driver data on disconnect to avoid NULL-pointer dereferences or use-after-free.
Metrics
CVSS 3.1 5.5/10
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:HWeakness enumeration
Affected software
| Vendor | Product | Versions |
|---|---|---|
| Linux | Linux | >= 88095e7b473a3d9ec3b9c60429576e9cbd327c89, < 6446516e626ce7c44bdadbcbb3d7677a2c52ce93; >= 88095e7b473a3d9ec3b9c60429576e9cbd327c89, < ba3b9429de94958dc0060d9816a915dd75c34919; >= 88095e7b473a3d9ec3b9c60429576e9cbd327c89, < 517b58e1d067115f80d198feee10192da4c424d0; >= 88095e7b473a3d9ec3b9c60429576e9cbd327c89, < 6468cab1173f44f7a4b7a05ce8abfdfd1ce1557a; >= 88095e7b473a3d9ec3b9c60429576e9cbd327c89, < 53f2642d77ab5f1f303388bff5500363c6cf962c; >= 88095e7b473a3d9ec3b9c60429576e9cbd327c89, < c83a282615d8f7ba28cebddd54600b419d562d82; >= 88095e7b473a3d9ec3b9c60429576e9cbd327c89, < 8d09e75759cb2afc0732acfb5a14a93c03805a61; >= 88095e7b473a3d9ec3b9c60429576e9cbd327c89, < dff34ef879c5e73298443956a8b391311ba78d57 |
| Linux | Linux | 3.0 |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP | >= V3.1.7, < * |
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.6, < * |
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.5, < * |
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP | >= V3.1.7, < * |
References
- https://git.kernel.org/stable/c/517b58e1d067115f80d198feee10192da4c424d0Patch
- https://git.kernel.org/stable/c/53f2642d77ab5f1f303388bff5500363c6cf962cPatch
- https://git.kernel.org/stable/c/6446516e626ce7c44bdadbcbb3d7677a2c52ce93Patch
- https://git.kernel.org/stable/c/6468cab1173f44f7a4b7a05ce8abfdfd1ce1557aPatch
- https://git.kernel.org/stable/c/8d09e75759cb2afc0732acfb5a14a93c03805a61Patch
- https://git.kernel.org/stable/c/ba3b9429de94958dc0060d9816a915dd75c34919Patch
- https://git.kernel.org/stable/c/c83a282615d8f7ba28cebddd54600b419d562d82Patch
- https://git.kernel.org/stable/c/dff34ef879c5e73298443956a8b391311ba78d57Patch
- https://cert-portal.siemens.com/productcert/html/ssa-019113.html
- https://cert-portal.siemens.com/productcert/html/ssa-082556.html
- https://cert-portal.siemens.com/productcert/html/ssa-457936.html
Timeline
- Published
- Apr 24, 2026
- Last modified
- Oct 15, 2026
- NVD status
- Modified