CVE-2026-2208

MediumCVSS 6.5/10Last modified Jun 17, 2026

Description

A security vulnerability has been detected in WeKan up to 8.20. Impacted is an unknown function of the file server/publications/rules.js of the component Rules Handler. The manipulation leads to missing authorization. The attack can be initiated remotely. Upgrading to version 8.21 is recommended to address this issue. The identifier of the patch is a787bcddf33ca28afb13ff5ea9a4cb92dceac005. The affected component should be upgraded.

Metrics

CVSS 3.1 6.5/10CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 8, 2026
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2026

CVE-2026-220808.7This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credeCVE-2026-220818.8This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flagCVE-2026-220828.8This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentiCVE-2026-22094.3A vulnerability was detected in WeKan up to 8.18. The affected element is the function setCreateTranslation of the file client/components/seCVE-2026-220939.5The EVbee Service Android app uses TLS encrypted communication (HTTPS), but does not validate the certificate provided by the server. This aCVE-2026-220949.3The firmware for the EVbee DC-80 has a weak hardcoded root password, which allows attackers to login as root using the SSH daemon that is exCVE-2026-220959.3The network diagnosis endpoint on the web server at port 8090 is vulnerable to command injection.CVE-2026-220969.3The webserver running on port 8090 does not require authentication. This allows for sensitive information leakage such as configured passworCVE-2026-220979.3The firmware update mechanism does not include cryptographic signature validation. This allows anyone with access to the firmware update capCVE-2026-220989.2Various sensitive information such as passwords and charging card UIDs are written to log files.CVE-2026-220998.7The charging station does not require authentication for Bluetooth commands to perform actions. The functionality exposed includes sensitiveCVE-2026-22107.2A vulnerability has been found in D-Link DIR-823X 250416. This affects the function sub_4211C8 of the file /goform/set_filtering. Such manip
CVE-2026-2208: Medium severity, CVSS 6.5 | Vulnix