CVE-2026-16687

CriticalCVSS 9.6/10Last modified Aug 25, 2026

Description

IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An unauthenticated attacker with network access can send the FSP a malformed request, allowing arbitrary code execution, giving the attacker full control over the managed system, resulting in a confidentiality, integrity, and availability impact.

Metrics

CVSS 3.1 9.6/10CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 19, 2026
Last modified
Aug 25, 2026
NVD status
Analyzed

Related CVEs from 2026

CVE-2026-166895.5IBM App Connect Enterprise 13.0.1.0 through 13.0.8.1, and 12.0.1.0 through 12.0.12.28 and IBM Integration Bus for z/OS 10.1.0.0 through 10.1CVE-2026-16697.5Arbitrary file read in the model loading mechanism (HDF5 integration) in Keras versions 3.0.0 through 3.13.1 on all supported platforms alloCVE-2026-166907.5IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote attacker to cause a denial of service due to uncontrolled resource consumCVE-2026-166926.5IBM i 7.6, 7.5, 7.4, and 7.3 could allow a remote authenticated attacker to cause a denial of service due to a stack-based buffer overflow.CVE-2026-166934.9IBM i 7.6, 7.5, 7.4, and 7.3 could allow a remote authenticated attacker to obtain sensitive information due to the use of hardcoded cryptogCVE-2026-166945.4IBM i 7.6, 7.5, 7.4, and 7.3 is vulnerable to stored cross-site scripting. This vulnerability allows an authenticated user to embed arbitrarCVE-2026-166957.8IBM i Access Client Solutions 1.1.2.0 through 1.1.9.13 could allow a local attacker to execute arbitrary code due to improper neutralizationCVE-2026-16709.8The affected products are vulnerable to an unauthenticated API endpoint exposure, which may allow an attacker to remotely change the "forgotCVE-2026-167026.5IBM Db2 11.5.0 through 11.5.9, and 12.1.0 through 12.1.5 for Linux, UNIX and Windows (includes DB2 Connect Server) could allow a remote authCVE-2026-167037.8IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a local attacker to gain elevated privileges due to improper privilege management.CVE-2026-167067.5IBM AIX 7.2, and 7.3 and IBM PowerVM VIOS 4.1 could allow a remote attacker to cause a denial of service due to an out-of-bounds write.CVE-2026-167078.2IBM PowerVM Hypervisor FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a v
CVE-2026-16687: Critical severity, CVSS 9.6 | Vulnix