Description
In the Linux kernel, the following vulnerability has been resolved:
net: hns3: add VLAN id validation before using
Currently, the VLAN id may be used without validation when receive a VLAN configuration mailbox from VF. The length of vlan_del_fail_bmap is BITS_TO_LONGS(VLAN_N_VID). It may cause out-of-bounds memory access once the VLAN id is bigger than or equal to VLAN_N_VID.
Therefore, VLAN id needs to be checked to ensure it is within the range of VLAN_N_VID.
Metrics
CVSS 3.1 7.1/10
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:HWeakness enumeration
Affected software
| Vendor | Product | Versions |
|---|---|---|
| Linux | Linux | >= fe4144d47eef8453459c53a34e9d5940a3e6c219, < 46c7d9fe8dd869ea5de666aba8c1ec1061ca44a8; >= fe4144d47eef8453459c53a34e9d5940a3e6c219, < 42c91dfa772c57de141e5a55a187ac760c0fd7e1; >= fe4144d47eef8453459c53a34e9d5940a3e6c219, < 00e56a7706e10b3d00a258d81fcb85a7e96372d6; >= fe4144d47eef8453459c53a34e9d5940a3e6c219, < b7b4f3bf118f51b67691a55b464f04452e5dc6fc; >= fe4144d47eef8453459c53a34e9d5940a3e6c219, < 95cca255a7a5ad782639ff0298c2a486707d1046; >= fe4144d47eef8453459c53a34e9d5940a3e6c219, < 91a51d01be5c9f82c12c2921ca5cceaa31b67128; >= fe4144d47eef8453459c53a34e9d5940a3e6c219, < 6ef935e65902bfed53980ad2754b06a284ea8ac1 |
| Linux | Linux | 5.3 |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0) | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0) | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0) | >= V3.1.7, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) | >= V3.1.6, < * |
| Siemens | SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0) | >= V3.1.7, < * |
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) | >= V3.1.6, < * |
| Siemens | SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0) | >= V3.1.7, < * |
References
- https://git.kernel.org/stable/c/00e56a7706e10b3d00a258d81fcb85a7e96372d6Patch
- https://git.kernel.org/stable/c/42c91dfa772c57de141e5a55a187ac760c0fd7e1Patch
- https://git.kernel.org/stable/c/46c7d9fe8dd869ea5de666aba8c1ec1061ca44a8Patch
- https://git.kernel.org/stable/c/6ef935e65902bfed53980ad2754b06a284ea8ac1Patch
- https://git.kernel.org/stable/c/91a51d01be5c9f82c12c2921ca5cceaa31b67128Patch
- https://git.kernel.org/stable/c/95cca255a7a5ad782639ff0298c2a486707d1046Patch
- https://git.kernel.org/stable/c/b7b4f3bf118f51b67691a55b464f04452e5dc6fcPatch
- https://cert-portal.siemens.com/productcert/html/ssa-019113.html
- https://cert-portal.siemens.com/productcert/html/ssa-457936.html
Timeline
- Published
- Jan 14, 2026
- Last modified
- Nov 10, 2026
- NVD status
- Modified