CVE-2025-69784

HighCVSS 8.8/10Last modified Jun 17, 2026

Description

A local, non-privileged attacker can abuse a vulnerable IOCTL interface exposed by the OpenEDR 2.5.1.0 kernel driver to modify the DLL injection path used by the product. By redirecting this path to a user-writable location, an attacker can cause OpenEDR to load an attacker-controlled DLL into high-privilege processes. This results in arbitrary code execution with SYSTEM privileges, leading to full compromise of the affected system.

Metrics

CVSS 3.1 8.8/10CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 16, 2026
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2025

CVE-2025-69798.8Captive Portal can allow authentication bypassCVE-2025-69807.5Captive Portal can expose sensitive informationCVE-2025-698067.5p2r3 bareiron commit: 8e4d4020d contains an Out-of-bounds Read, which allows unauthenticated remote attackers to get relative information leCVE-2025-698077.5p2r3 Bareiron commit: 8e4d4020d is vulnerable to Buffer Overflow, which allows unauthenticated remote attackers to cause a denial of serviceCVE-2025-698089.1An out-of-bounds memory access (OOB) in p2r3 Bareiron commit 8e4d40 allows unauthenticated attackers to access sensitive information and cauCVE-2025-698099.8A write-what-where condition in p2r3 Bareiron commit 8e4d40 allows unauthenticated attackers to write arbitrary values to memory, enabling aCVE-2025-69814.3An incorrect authorization vulnerability allowed unauthorized read access to the contents of internal repositories for contractor accounts wCVE-2025-69826.9Use of Hard-coded Credentials in TP-Link Archer C50 V3( <= 180703)/V4( <= 250117 )/V5( <= 200407 ), and C20 V5 (<US_V5_260419 orCVE-2025-698206.0Directory Traversal vulnerability in Beam beta9 v.0.1.521 allows a remote attacker to obtain sensitive information via the joinCleanPath funCVE-2025-698217.4An issue in Beat XP VEGA Smartwatch (Firmware Version - RB303ATV006229) allows an attacker to cause a denial of service via the BLE connectiCVE-2025-698227.4An issue in Atomberg Atomberg Erica Smart Fan Firmware Version: V1.0.36 allows an attacker to obtain sensitive information and escalate privCVE-2025-6982810.0File Upload vulnerability in TMS Global Software TMS Management Console v.6.3.7.27386.20250818 allows a remote attacker to execute arbitrary
CVE-2025-69784: High severity, CVSS 8.8 | Vulnix