CVE-2025-67090

MediumCVSS 5.1/10Last modified Jun 17, 2026

Description

The LuCI web interface on Gl Inet GL.Inet AX1800 Version 4.6.4 & 4.6.8 are vulnerable. Fix available in version 4.8.2 GL.Inet AX1800 Version 4.6.4 & 4.6.8 lacks rate limiting or account lockout mechanisms on the authentication endpoint (`/cgi-bin/luci`). An unauthenticated attacker on the local network can perform unlimited password attempts against the admin interface.

Metrics

CVSS 3.1 5.1/10CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jan 8, 2026
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2025

CVE-2025-670916.5An issue in GL Inet GL.Inet AX1800 Version 4.6.4 & 4.6.8 are vulnerable. GL.Inet AX1800 Version 4.6.4 & 4.6.8 in the GL.iNet custom opkg wraCVE-2025-67107.5MongoDB Server may be susceptible to stack overflow due to JSON parsing mechanism, where specifically crafted JSON inputs may induce unwarraCVE-2025-671027.6A SQL injection vulnerability in the alldayoffs feature in Jorani up to v1.0.4, allows an authenticated attacker to execute arbitrary SQL coCVE-2025-6710810.0eProsima Fast-DDS v3.3 was discovered to contain improper validation for ticket revocation, resulting in insecure communications and connectCVE-2025-6710910.0Improper verification of the time certificate in Eclipse Cyclone DDS before v0.10.5 allows attackers to bypass certificate checks and executCVE-2025-67114.9An issue has been identified in MongoDB Server where unredacted queries may inadvertently appear in server logs when certain error conditionCVE-2025-671117.5An integer overflow in the RTPS protocol implementation of OpenDDS DDS before v3.33.0 allows attackers to cause a Denial of Service (DoS) viCVE-2025-671129.8Use of a hard-coded AES-256-CBC key in the configuration backup/restore implementation of Small Cell Sercomm SCE4255W (FreedomFi Englewood) CVE-2025-671139.8OS command injection in the CWMP client (/ftl/bin/cwmp) of Small Cell Sercomm SCE4255W (FreedomFi Englewood) firmware before DG3934v3@230804CVE-2025-671149.8Use of a deterministic credential generation algorithm in /ftl/bin/calc_f2 in Small Cell Sercomm SCE4255W (FreedomFi Englewood) firmware befCVE-2025-671156.5A path traversal vulnerability in /ftl/web/setup.cgi in Small Cell Sercomm SCE4255W (FreedomFi Englewood) firmware before DG3934v3@230804184CVE-2025-67126.5MongoDB Server may be susceptible to disruption caused by high memory usage, potentially leading to server crash. This condition is linked t
CVE-2025-67090: Medium severity, CVSS 5.1 | Vulnix