CVE-2025-59097

CriticalCVSS 9.3/10Last modified Jun 17, 2026

Description

The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.

This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication: - Re-configure Access Managers (e.g. remove alarming system requirements) - Freely re-configure the inputs and outputs - Open all connected doors permanently - Open all doors for a defined time interval - Change the admin password - and many more

Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet.

Metrics

CVSS 4.0 9.3/10CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jan 26, 2026
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2025

CVE-2025-590988.7The Access Manager is offering a trace functionality to debug errors and issues with the device. The trace functionality is implemented as aCVE-2025-590998.8The Access Manager is using the open source web server CompactWebServer written in C#. This web server is affected by a path traversal vulneCVE-2025-59108.8A vulnerability has been found in TOTOLINK EX1200T up to 4.1.2cu.5232_B20210713 and classified as critical. Affected by this vulnerability iCVE-2025-591005.9The web interface offers a functionality to export the internal SQLite database. After executing the database export, an automatic download CVE-2025-591017.7Instead of typical session tokens or cookies, it is verified on a per-request basis if the originating IP address has once successfully loggCVE-2025-591026.9The web server of the Access Manager offers a functionality to download a backup of the local database stored on the device. This database cCVE-2025-591039.2The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new haCVE-2025-591047.0With physical access to the device and enough time an attacker is able to solder test leads to the debug footprint (or use the 6-Pin tag-conCVE-2025-591057.0With physical access to the device and enough time an attacker can desolder the flash memory, modify it and then reinstall it because of misCVE-2025-591068.8The binary serving the web server and executing basically all actions launched from the Web UI is running with root privileges. This is agaiCVE-2025-591078.5Dormakaba provides the software FWServiceTool to update the firmware version of the Access Managers via the network. The firmware in some inCVE-2025-591089.2By default, the password for the Access Manager's web interface, is set to 'admin'. In the tested version changing the password was not enfo