Description

The CS5000 Fire Panel is vulnerable due to a default account that exists on the panel. Even though it is possible to change this by SSHing into the device, it has remained unchanged on every installed system observed. This account is not root but holds high-level permissions that could severely impact the device's operation if exploited.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
May 30, 2025
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2025

CVE-2025-414395.1A reflected cross-site scripting vulnerability via a specific parameter exists in SLNX Help Documentation of RICOH Streamline NX. If this vuCVE-2025-41449.8PKCE was implemented in the OAuth implementation in workers-oauth-provider that is part of MCP framework https://github.com/cloudflare/workCVE-2025-414415.3Mailform Pro CGI prior to 4.3.4 generates error messages containing sensitive information, which may allow a remote unauthenticated attackerCVE-2025-414425.4A vulnerability exists in Advantech iView versions prior to 5.7.05 build 7057, which could allow a reflected cross-site scripting (XSS) attCVE-2025-414434.3Mattermost versions 10.5.x <= 10.5.12, 10.11.x <= 10.11.2 fail to properly validate guest user permissions when accessing channel informatioCVE-2025-414448.3Zohocorp ManageEngine ADAudit Plus versions 8510 and prior are vulnerable to authenticated SQL injection in the alerts module.CVE-2025-41459.8A vulnerability, which was classified as critical, has been found in Netgear EX6200 1.0.3.94. This issue affects the function sub_3D0BC. TheCVE-2025-414508.2Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2CVE-2025-414518.7Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command ('Command Injection') in Danfoss AK-SM8xxA Series CVE-2025-414526.8Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, CVE-2025-414585.5Unencrypted storage in the database in Two App Studio Journey v5.5.9 for iOS allows local attackers to extract sensitive data via direct accCVE-2025-414597.8Insufficient protection against brute-force and runtime manipulation in the local authentication component in Two App Studio Journey 5.5.6 o
CVE-2025-41438: Critical severity, CVSS 9.8 | Vulnix