CVE-2025-4145

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

A vulnerability, which was classified as critical, has been found in Netgear EX6200 1.0.3.94. This issue affects the function sub_3D0BC. The manipulation of the argument host leads to buffer overflow. The attack may be initiated remotely. The vendor was contacted early about this disclosure but did not respond in any way.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
May 1, 2025
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2025

CVE-2025-414508.2Improper Authentication vulnerability in Danfoss AKSM8xxA Series.This issue affects Danfoss AK-SM 8xxA Series prior to version 4.2CVE-2025-414518.7Improper neutralization of alarm-to-mail configuration fields used in an OS shell Command ('Command Injection') in Danfoss AK-SM8xxA Series CVE-2025-414526.8Post-authenticated external control of system web interface configuration setting vulnerability in Danfoss AK-SM8xxA Series prior to 4.3.1, CVE-2025-414585.5Unencrypted storage in the database in Two App Studio Journey v5.5.9 for iOS allows local attackers to extract sensitive data via direct accCVE-2025-414597.8Insufficient protection against brute-force and runtime manipulation in the local authentication component in Two App Studio Journey 5.5.6 oCVE-2025-41469.8A vulnerability, which was classified as critical, was found in Netgear EX6200 1.0.3.94. Affected is the function sub_41940. The manipulatioCVE-2025-41479.8A vulnerability has been found in Netgear EX6200 1.0.3.94 and classified as critical. Affected by this vulnerability is the function sub_47FCVE-2025-41489.8A vulnerability was found in Netgear EX6200 1.0.3.94 and classified as critical. Affected by this issue is the function sub_503FC. The manipCVE-2025-41499.8A vulnerability was found in Netgear EX6200 1.0.3.94. It has been classified as critical. This affects the function sub_54014. The manipulatCVE-2025-41509.8A vulnerability was found in Netgear EX6200 1.0.3.94. It has been declared as critical. This vulnerability affects the function sub_54340. TCVE-2025-41519.8A vulnerability was found in PHPGurukul Curfew e-Pass Management System 1.0. It has been rated as critical. This issue affects some unknown CVE-2025-41529.8A vulnerability classified as critical has been found in PHPGurukul Online Birth Certificate System 1.0. Affected is an unknown function of
CVE-2025-4145: Critical severity, CVSS 9.8 | Vulnix