CVE-2025-40584

MediumCVSS 5.5/10Last modified Jun 17, 2026

Description

A vulnerability has been identified in SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions < V5.7 SP1 HF1), SIMOTION SCOUT V5.4 (All versions), SIMOTION SCOUT V5.5 (All versions), SIMOTION SCOUT V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT V5.7 (All versions < V5.7 SP1 HF1), SINAMICS STARTER V5.5 (All versions), SINAMICS STARTER V5.6 (All versions), SINAMICS STARTER V5.7 (All versions < V5.7 HF2). The affected application contains a XML External Entity Injection (XXE) vulnerability while parsing specially crafted XML files. This could allow an attacker to read arbitrary files in the system.

Metrics

CVSS 3.1 5.5/10CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 12, 2025
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2025

CVE-2025-405859.9A vulnerability has been identified in Energy Services (All versions with G5DFR). Affected solutions using G5DFR contain default credentialsCVE-2025-405877.6A vulnerability has been identified in Polarion V2404 (All versions < V2404.5), Polarion V2410 (All versions < V2410.2). The affected applicCVE-2025-40597.8A vulnerability classified as critical was found in code-projects Prison Management System 1.0. This vulnerability affects the function addrCVE-2025-405917.7A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.5), RUGGEDCOM ROX MX5000RE (All versions < V2.16.5), RUGGECVE-2025-405926.1A vulnerability has been identified in Mendix Studio Pro 10 (All versions < V10.24.24 for Windows), Mendix Studio Pro 10 (All versions < V10CVE-2025-405936.5A vulnerability has been identified in SIMATIC CN 4100 (All versions < V4.0). The affected application allows to control the device by storiCVE-2025-405949.8A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS CVE-2025-405957.2A Server-side request forgery (SSRF) vulnerability has been identified in the SMA1000 Appliance Work Place interface. By using an encoded URCVE-2025-405967.3A Stack-based buffer overflow vulnerability in the SMA100 series web interface allows remote, unauthenticated attacker to cause Denial of SeCVE-2025-405977.5A Heap-based buffer overflow vulnerability in the SMA100 series web interface allows remote, unauthenticated attacker to cause Denial of SerCVE-2025-405986.1A Reflected cross-site scripting (XSS) vulnerability exists in the SMA100 series web interface, allowing a remote unauthenticated attacker tCVE-2025-405999.1An authenticated arbitrary file upload vulnerability exists in the SMA 100 series web management interface. A remote attacker with administr
CVE-2025-40584: Medium severity, CVSS 5.5 | Vulnix