CVE-2025-36747

CriticalCVSS 9.8/10Last modified Oct 7, 2026

Description

ShineLan-X contains a set of credentials for an FTP server was found within the firmware, allowing testers to establish an insecure FTP connection with the server. This may allow an attacker to replace legitimate files being deployed to devices with their own malicious versions, since the firmware signature verification is not enforced.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Dec 13, 2025
Last modified
Oct 7, 2026
NVD status
Analyzed

Related CVEs from 2025

CVE-2025-367485.4ShineLan-X contains a stored cross site scripting (XSS) vulnerability in the local configuration web server. The JavaScript code snippet canCVE-2025-36755.3A vulnerability was found in TOTOLINK A3700R 9.1.2u.5822_B20200513. It has been rated as critical. Affected by this issue is the function seCVE-2025-367505.4ShineLan-X contains a stored cross site scripting (XSS) vulnerability in the Plant Name field. A HTML payload will be displayed on the plantCVE-2025-367519.4Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the netCVE-2025-367529.8Growatt ShineLan-X communication dongle has an undocumented backup account with undocumented credentials which allows significant level acceCVE-2025-367539.8The SWD debug interface on the Growatt ShineLan-X communication dongle is available by default, allowing an attacker to attain debug access CVE-2025-367549.3The authentication mechanism on web interface is not properly implemented. It is possible to bypass authentication checks by crafting a postCVE-2025-367552.4The CleverDisplay BlueOne hardware player is designed with its USB interfaces physically enclosed and inaccessible under normal operating coCVE-2025-367565.8A problem with missing authorization on SolaX Cloud platform allows taking over any SolaX solarpanel inverter of which the serial number is CVE-2025-367576.3It is possible to bypass the administrator login screen on SolaX Cloud. An attacker could use parameter tampering to bypass the login screenCVE-2025-367586.3It is possible to bypass the clipping level of authentication attempts in SolaX Cloud through the use of the 'Forgot Password' functionalityCVE-2025-367598.7Through the provision of user names, SolaX Cloud will suggest (similar) user accounts and thereby leak sensitive information such as user em
CVE-2025-36747: Critical severity, CVSS 9.8 | Vulnix