CVE-2025-30237

HighCVSS 8.7/10Last modified Oct 9, 2026

Description

The affected TP-Link Aginet devices contain a flaw in the web management interface where authentication checks are not consistently enforced on certain endpoints. An attacker can send specially crafted requests to bypass authentication and directly invoke privileged functionality without valid credentials. This issue arises from improper enforcement of access control mechanisms on sensitive operations.

Successful exploitation may allow an unauthenticated attacker to execute privileged operations and gain full control of the device.

Metrics

CVSS 4.0 8.7/10CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X

Weakness enumeration

Affected software

Source: the vendor's advisory (CNA). NVD analysis pending.

No affected versions have been published.

Timeline

Published
Aug 10, 2026
Last modified
Oct 9, 2026
NVD status
Awaiting Analysis

Related CVEs from 2025

CVE-2025-302388.6In affected TP-Link Aginet devices, insufficient authorization validation allows authenticated low-privileged users to execute higher-privilCVE-2025-302398.5In affected TP-Link Aginet devices, use of hardcoded cryptographic keys embedded in the firmware to protect sensitive configuration data mayCVE-2025-302405.1The affected TP-Link Aginet devices do not properly validate symbolic links created on external USB storage devices. By placing a crafted syCVE-2025-302418.6Certain web interface components in affected TP-Link Aginet devices do not validate and sanitize user-supplied input properly before passingCVE-2025-302479.3An OS command injection vulnerability in user interface in Western Digital My Cloud firmware prior to 5.31.108 on NAS platforms allows remotCVE-2025-302488.9DLL hijacking in the WD Discovery Installer in Western Digital WD Discovery 5.2.730 on Windows allows a local attacker to execute arbitrary CVE-2025-30257.3Elevation of Privileges in the cleaning feature of Gen Digital CCleaner version 6.33.11465 on Windows allows a local user to gain SYSTEM priCVE-2025-302545.3An unauthenticated attacker can obtain a serial number of a smart meter(s) using its owner's username.CVE-2025-302558.2Out-of-bounds write for some Intel(R) PROSet/Wireless WiFi Software for Windows before version 23.160 within Ring 2: Device Drivers may alloCVE-2025-302567.5A denial of service vulnerability exists in the HTTP Header Parsing functionality of Tenda AC6 V5.0 V02.03.01.110. A specially crafted serieCVE-2025-302575.3Unauthenticated attackers can retrieve serial number of smart meters associated to a specific user account.CVE-2025-302584.7In GnuPG before 2.5.5, if a user chooses to import a certificate with certain crafted subkey data that lacks a valid backsig or that has inc
CVE-2025-30237: High severity, CVSS 8.7 | Vulnix