A vulnerability was found in Netis WF-2404 1.1.124EN. It has been declared as critical. This vulnerability affects unknown code of the component UART. The manipulation leads to hardware allows activation of test or debug logic at runtime. It is possible to launch the attack on the physical device. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Metrics

CVSS 3.1 6.8/10CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 28, 2025
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2025

CVE-2025-291926.1Flowise before 3.0.5 allows XSS via a FORM element and an INPUT element when an admin views the chat log.CVE-2025-29202.0A vulnerability was found in Netis WF-2404 1.1.124EN. It has been rated as problematic. This issue affects some unknown processing of the fiCVE-2025-292086.5CodeZips Gym Management System v1.0 is vulnerable to SQL injection in the name parameter within /dashboard/admin/deleteroutine.php.CVE-2025-292099.8TOTOLINK X18 v9.1.0cu.2024_B20220329 has an unauthorized arbitrary command execution in the enable parameter' of the sub_41105C function of CVE-2025-29216.4A vulnerability classified as critical has been found in Netis WF-2404 1.1.124EN. Affected is an unknown function of the file /etc/passwd. TCVE-2025-292135.5A zip slip vulnerability in the component \service\migrate\MigrateForm.java of JEEWMS v3.7 allows attackers to execute arbitrary code via a CVE-2025-292147.5Tenda AX12 v22.03.01.46_CN was discovered to contain a stack overflow via the sub_42F69C function at /goform/setMacFilterCfg.CVE-2025-292156.5Tenda AX12 v22.03.01.46_CN was discovered to contain a stack overflow via the sub_43fdcc function at /goform/SetNetControlList.CVE-2025-292176.5Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiSSID parameter at /goform/setModules. This vulnerability aCVE-2025-292186.5Tenda W18E v2.0 v16.01.0.11 was discovered to contain a stack overflow in the wifiPwd parameter at /goform/setModules. This vulnerability alCVE-2025-29222.0A vulnerability classified as problematic was found in Netis WF-2404 1.1.124EN. Affected by this vulnerability is an unknown functionality oCVE-2025-292236.3Linksys E5600 v1.1.0.26 was discovered to contain a command injection vulnerability via the pt parameter in the traceRoute function.
CVE-2025-2919: Medium severity, CVSS 6.8 | Vulnix