Description

A deserialization of untrusted input vulnerability exists in the cvhDecapsulateCmd functionality of Dell ControlVault3 prior to 5.15.10.14 and ControlVault3 Plus prior to 6.2.26.36. A specially crafted ControlVault response to a command can lead to arbitrary code execution. An attacker can compromise a ControlVault firmware and have it craft a malicious response to trigger this vulnerability.

Metrics

CVSS 3.1 8.1/10CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jun 13, 2025
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2025

CVE-2025-24929.2An improper authentication control vulnerability exists in AiCloud. This vulnerability can be triggered by a crafted request, potentially leCVE-2025-249204.3Mattermost versions 10.4.x <= 10.4.2, 10.3.x <= 10.3.3, 9.11.x <= 9.11.8, 10.5.x <= 10.5.0 fail to restrict bookmark creation and updates inCVE-2025-249216.6Improper neutralization for some Edge Orchestrator software before version 24.11.1 for Intel(R) Tiber(TM) Edge Platform may allow an unautheCVE-2025-249228.8A stack-based buffer overflow vulnerability exists in the securebio_identify functionality of Dell ControlVault3 prior to 5.15.10.14 and DeCVE-2025-249236.7Uncontrolled search path in some Intel(R) AI for Enterprise Retrieval-augmented Generation software may allow an authenticated user to potenCVE-2025-249249.8Certain functionality within GMOD Apollo does not require authentication when passed with an administrative usernameCVE-2025-249255.5in OpenHarmony v5.0.3 and prior versions allow a local attacker case DOS through missing release of memory.CVE-2025-249287.7libxml2 before 2.12.10 and 2.13.x before 2.13.6 has a stack-based buffer overflow in xmlSnprintfElements in valid.c. To exploit this, DTD vaCVE-2025-24937.5Path Traversal vulnerability in Softdial Contact Center of Sytel Ltd. This vulnerability allows an attacker to manipulate the ‘id’ parameterCVE-2025-249345.4Software which sets SO_REUSEPORT_LB on a socket and then connects it to a host will not directly observe any problems. However, due to its CVE-2025-249369.0The web application allows user input to pass unfiltered to a command executed on the underlying operating system. The vulnerable component CVE-2025-249379.0File contents could be read from the local file system by an attacker. Additionally, malicious code could be inserted in the file, leading t
CVE-2025-24919: High severity, CVSS 8.1 | Vulnix