CVE-2024-9779

HighCVSS 7.5/10Last modified Jun 17, 2026

Description

A flaw was found in Open Cluster Management (OCM) when a user has access to the worker nodes which contain the cluster-manager or klusterlet deployments. The cluster-manager deployment uses a service account with the same name "cluster-manager" which is bound to a ClusterRole also named "cluster-manager", which includes the permission to create Pod resources. If this deployment runs a pod on an attacker-controlled node, the attacker can obtain the cluster-manager's token and steal any service account token by creating and mounting the target service account to control the whole cluster.

Metrics

CVSS 3.1 7.5/10CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Dec 17, 2024
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2024

CVE-2024-97805.5ITS dissector crash in Wireshark 4.4.0 allows denial of service via packet injection or crafted capture fileCVE-2024-97817.5AppleTalk and RELOAD Framing dissector crash in Wireshark 4.4.0 and 4.2.0 to 4.2.7 allows denial of service via packet injection or crafted CVE-2024-97828.8A vulnerability was found in D-Link DIR-619L B1 2.06. It has been declared as critical. This vulnerability affects the function formEasySetuCVE-2024-97838.8A vulnerability was found in D-Link DIR-619L B1 2.06. It has been rated as critical. This issue affects the function formLogDnsquery of the CVE-2024-97848.8A vulnerability classified as critical has been found in D-Link DIR-619L B1 2.06. Affected is the function formResetStatistic of the file /gCVE-2024-97858.8A vulnerability classified as critical was found in D-Link DIR-619L B1 2.06. Affected by this vulnerability is the function formSetDDNS of tCVE-2024-97868.8A vulnerability, which was classified as critical, has been found in D-Link DIR-619L B1 2.06. Affected by this issue is the function formSetCVE-2024-97875.3A vulnerability, which was classified as problematic, was found in Contemporary Control System BASrouter BACnet BASRT-B 2.7.2. This affects CVE-2024-97887.2A vulnerability has been found in LyLme_spage 1.9.5 and classified as critical. This vulnerability affects unknown code of the file /admin/tCVE-2024-97897.2A vulnerability was found in LyLme_spage 1.9.5 and classified as critical. This issue affects some unknown processing of the file /admin/appCVE-2024-97907.2A vulnerability was found in LyLme_spage 1.9.5. It has been classified as critical. Affected is an unknown function of the file /admin/sou.pCVE-2024-97926.1A vulnerability classified as problematic has been found in D-Link DSL-2750U R5B017. This affects an unknown part of the component Port Forw
CVE-2024-9779: High severity, CVSS 7.5 | Vulnix