CVE-2024-48955

HighCVSS 8.1/10Last modified Jun 17, 2026

Description

Broken access control in NetAdmin 4.030319 returns data with functionalities on the endpoint that "assembles" the functionalities menus, the return of this call is not encrypted and as the system does not validate the session authorization, an attacker can copy the content of the browser of a user with greater privileges having access to the functionalities of the user that the code was copied.

Metrics

CVSS 3.1 8.1/10CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Oct 29, 2024
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2024

CVE-2024-489569.8Serviceware Processes 6.0 through 7.3 before 7.4 allows attackers without valid authentication to send a specially crafted HTTP request to aCVE-2024-489577.8execute_filter_audio in archive_read_support_format_rar.c in libarchive before 3.7.5 allows out-of-bounds access via a crafted archive file CVE-2024-489587.8execute_filter_delta in archive_read_support_format_rar.c in libarchive before 3.7.5 allows out-of-bounds access via a crafted archive file CVE-2024-48965.4The WPB Elementor Addons plugin for WordPress is vulnerable to Stored Cross-Site Scripting via the ‘url’ parameter in all versions up to, anCVE-2024-489628.8Improper Control of Generation of Code ('Code Injection'), Cross-Site Request Forgery (CSRF), : Improper Neutralization of Special Elements CVE-2024-489639.8The package Snyk CLI before 1.1294.0 is vulnerable to Code Injection when scanning an untrusted PHP project. The vulnerability can be triggeCVE-2024-489648.8The package Snyk CLI before 1.1294.0 is vulnerable to Code Injection when scanning an untrusted Gradle project. The vulnerability can be triCVE-2024-4896610.0The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access CVE-2024-4896710.0The ventilator and the Service PC lack sufficient audit logging capabilities to allow for detection of malicious activity and subsequent forCVE-2024-48978.4parisneo/lollms-webui, in its latest version, is vulnerable to remote code execution due to an insecure dependency on llama-cpp-python versiCVE-2024-489709.3The ventilator's microcontroller lacks memory protection. An attacker could connect to the internal JTAG interface and read or write to flasCVE-2024-489719.3The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attack