CVE-2024-45754

HighCVSS 7.2/10Last modified Jun 17, 2026

Description

An issue was discovered in the centreon-bi-server component in Centreon BI Server 24.04.x before 24.04.3, 23.10.x before 23.10.8, 23.04.x before 23.04.11, and 22.10.x before 22.10.11. SQL injection can occur in the listing of configured reporting jobs. Exploitation is only accessible to authenticated users with high-privileged access.

Metrics

CVSS 3.1 7.2/10CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Oct 11, 2024
Last modified
Jun 17, 2026
NVD status
Deferred

Related CVEs from 2024

CVE-2024-457557.2An issue was discovered in Centreon centreon-dsm-server 24.10.x before 24.10.0, 24.04.x before 24.04.3, 23.10.x before 23.10.1, 23.04.x befoCVE-2024-457567.2An issue was discovered in Centreon centreon-open-tickets 24.10.x before 24.10.0, 24.04.x before 24.04.2, 23.10.x before 23.10.1, 23.04.x beCVE-2024-457577.2An issue was discovered in Centreon centreon-bam 24.04, 23.10, 23.04, and 22.10. SQL injection can occur in the user-settings form. ExploitaCVE-2024-457589.1H2O.ai H2O through 3.46.0.4 allows attackers to arbitrarily set the JDBC URL, leading to deserialization attacks, file reads, and command exCVE-2024-457597.3Dell PowerProtect Data Domain, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an escalation of privilege vulnerabilCVE-2024-45765.3The component listed above contains a vulnerability that allows an attacker to traverse directories and access sensitive files, leading to uCVE-2024-457608.8Dell OpenManage Server Administrator, versions 11.0.1.0 and prior, contains an improper access control vulnerability. A remote low privilegeCVE-2024-457618.1Dell OpenManage Server Administrator, versions 11.0.1.0 and prior, contains an improper input validation vulnerability. A remote low-privileCVE-2024-457637.2Dell Enterprise SONiC OS, version(s) 4.1.x, 4.2.x, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS CommCVE-2024-457649.8Dell Enterprise SONiC OS, version(s) 4.1.x, 4.2.x, contain(s) a Missing Critical Step in Authentication vulnerability. An unauthenticated atCVE-2024-457657.2Dell Enterprise SONiC OS, version(s) 4.1.x, 4.2.x, contain(s) an Improper Neutralization of Special Elements used in an OS Command ('OS CommCVE-2024-457668.8Dell OpenManage Enterprise, version(s) OME 4.1 and prior, contain(s) an Improper Control of Generation of Code ('Code Injection') vulnerabil
CVE-2024-45754: High severity, CVSS 7.2 | Vulnix