CVE-2024-41162

MediumCVSS 4.3/10Last modified Jun 17, 2026

Description

Mattermost versions 9.9.x <= 9.9.0, 9.5.x <= 9.5.6, 9.7.x <= 9.7.5 and 9.8.x <= 9.8.1 fail to disallow the modification of local channels by a remote, when shared channels are enabled, which allows a malicious remote to make an arbitrary local channel read-only.

Metrics

CVSS 3.1 4.3/10CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 1, 2024
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2024

CVE-2024-411637.5A directory traversal vulnerability exists in the archive functionality of Veertu Anka Build 1.42.0. A specially crafted HTTP request can leCVE-2024-411647.5When TCP profile with Multipath TCP enabled (MPTCP) is configured on a Virtual Server, undisclosed traffic along with conditions beyond the CVE-2024-411659.1A library injection vulnerability exists in Microsoft Word 16.83 for macOS. A specially crafted library can leverage Word's access privilegeCVE-2024-411666.1Stack-based buffer overflow in some Intel(R) PROSet/Wireless WiFi and Killerâ„¢ WiFi software for Windows before version 23.80 may allow an CVE-2024-411676.7Improper input validation in UEFI firmware in some Intel(R) Server Board M10JNP2SB Family may allow a privileged user to potentially enable CVE-2024-411687.4Use after free in some Intel(R) PROSet/Wireless WiFi and Killerâ„¢ WiFi software for Windows before version 23.80 may allow an unauthenticatCVE-2024-411697.5The attacker can use the raft server protocol in an unauthenticated way. The attacker can see the server's resources, including directories CVE-2024-41178.8A vulnerability was found in Tenda W15E 15.11.0.14 and classified as critical. Affected by this issue is the function formDelPortMapping of CVE-2024-411707.8A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0015), Tecnomatix Plant Simulation V2404 (AllCVE-2024-411718.8A vulnerability has been identified in SINUMERIK 828D V4 (All versions), SINUMERIK 828D V5 (All versions < V5.24), SINUMERIK 840D sl V4 (AllCVE-2024-411727.5In versions of Apache CXF before 3.6.4 and 4.0.5 (3.5.x and lower versions are not impacted), a CXF HTTP client conduit may prevent HTTPClieCVE-2024-411737.8The IPC-Diagnostics package included in TwinCAT/BSD is vulnerable to a local authentication bypass by a low privileged attacker.
CVE-2024-41162: Medium severity, CVSS 4.3 | Vulnix