Description
A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-261790 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Metrics
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HWeakness enumeration
Affected software
| Vendor | Product | Versions |
|---|---|---|
| Tenda | AC8 | 16.03.34.09 |
| tenda | ac8_firmware | 16.03.34.09 |
References
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.mdExploit, Third Party Advisory
- https://vuldb.com/?ctiid.261790Permissions Required, VDB Entry
- https://vuldb.com/?id.261790Third Party Advisory, VDB Entry
- https://vuldb.com/?submit.316493Third Party Advisory, VDB Entry
- https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.mdExploit, Third Party Advisory
- https://vuldb.com/?ctiid.261790Permissions Required, VDB Entry
- https://vuldb.com/?id.261790Third Party Advisory, VDB Entry
- https://vuldb.com/?submit.316493Third Party Advisory, VDB Entry
Timeline
- Published
- Apr 23, 2024
- Last modified
- Jun 17, 2026
- NVD status
- Analyzed