CVE-2024-36977

MediumCVSS 5.5/10Last modified Aug 4, 2026

Description

In the Linux kernel, the following vulnerability has been resolved:

usb: dwc3: Wait unconditionally after issuing EndXfer command

Currently all controller IP/revisions except DWC3_usb3 >= 310a wait 1ms unconditionally for ENDXFER completion when IOC is not set. This is because DWC_usb3 controller revisions >= 3.10a supports GUCTL2[14: Rst_actbitlater] bit which allows polling CMDACT bit to know whether ENDXFER command is completed.

Consider a case where an IN request was queued, and parallelly soft_disconnect was called (due to ffs_epfile_release). This eventually calls stop_active_transfer with IOC cleared, hence send_gadget_ep_cmd() skips waiting for CMDACT cleared during EndXfer. For DWC3 controllers with revisions >= 310a, we don't forcefully wait for 1ms either, and we proceed by unmapping the requests. If ENDXFER didn't complete by this time, it leads to SMMU faults since the controller would still be accessing those requests.

Fix this by ensuring ENDXFER completion by adding 1ms delay in __dwc3_stop_active_transfer() unconditionally.

Metrics

CVSS 3.1 5.5/10CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H

Affected software

No affected versions have been published.

Timeline

Published
Jun 18, 2024
Last modified
Aug 4, 2026
NVD status
Modified

Related CVEs from 2024

CVE-2024-369787.8In the Linux kernel, the following vulnerability has been resolved: net: sched: sch_multiq: fix possible OOB write in multiq_tune() q->banCVE-2024-369797.8In the Linux kernel, the following vulnerability has been resolved: net: bridge: mst: fix vlan use-after-free syzbot reported a suspiciousCVE-2024-36988.8A vulnerability was found in Campcodes House Rental Management System 1.0. It has been declared as critical. Affected by this vulnerability CVE-2024-369807.5An out-of-bounds read vulnerability exists in the OpenPLC Runtime EtherNet/IP PCCC parser functionality of OpenPLC_v3 b4702061dc14d1024856f7CVE-2024-369817.5An out-of-bounds read vulnerability exists in the OpenPLC Runtime EtherNet/IP PCCC parser functionality of OpenPLC_v3 b4702061dc14d1024856f7CVE-2024-369827.5In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10 and Splunk Cloud Platform versions below 9.1.2312.109 and 9.1.2308.207, an attaCVE-2024-369838.8In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10 and Splunk Cloud Platform versions below 9.1.2312.109 and 9.1.2308.207, an authCVE-2024-369848.8In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10 on Windows, an authenticated user could execute a specially crafted query that CVE-2024-369858.8In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10, a low-privileged user that does not hold the admin or power Splunk roles couldCVE-2024-369865.7In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10 and Splunk Cloud Platform versions below 9.1.2312.200 and 9.1.2308.207, an authCVE-2024-369876.5In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10 and Splunk Cloud Platform versions below 9.1.2312.200, an authenticated, low-prCVE-2024-369894.3In Splunk Enterprise versions below 9.2.2, 9.1.5, and 9.0.10 and Splunk Cloud Platform versions below 9.1.2312.200, a low-privileged user th
CVE-2024-36977: Medium severity, CVSS 5.5 | Vulnix