CVE-2024-3204

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

A vulnerability has been found in c-blosc2 up to 2.13.2 and classified as critical. Affected by this vulnerability is the function ndlz4_decompress of the file /src/c-blosc2/plugins/codecs/ndlz/ndlz4x4.c. The manipulation leads to heap-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. Upgrading to version 2.14.3 is able to address this issue. It is recommended to upgrade the affected component. The associated identifier of this vulnerability is VDB-259051.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 2, 2024
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2024

CVE-2024-320409.8FreeRDP is a free implementation of the Remote Desktop Protocol. FreeRDP based clients that use a version of FreeRDP prior to 3.5.0 or 2.11.CVE-2024-320419.8FreeRDP is a free implementation of the Remote Desktop Protocol. FreeRDP based clients that use a version of FreeRDP prior to 3.5.0 or 2.11.CVE-2024-320427.5The key used to encrypt passwords stored in the database can be found in the CyberPower PowerPanel application code, allowing the passworCVE-2024-320446.8Improper access control for some Intel(R) Arc(TM) Pro Graphics for Windows drivers before version 31.0.101.5319 may allow an authenticated uCVE-2024-320455.9Mattermost versions 9.5.x <= 9.5.3, 9.6.x <= 9.6.1, 8.1.x <= 8.1.12 fail to enforce proper access controls for channel and team membership wCVE-2024-320464.3Mattermost versions 9.6.x <= 9.6.0, 9.5.x <= 9.5.2, 9.4.x <= 9.4.4 and 8.1.x <= 8.1.11 fail to remove detailed error messages in API requestCVE-2024-320479.8Hard-coded credentials for the CyberPower PowerPanel test server can be found in the production code. This might result in an attacker gaiCVE-2024-320486.5Improper input validation in the Intel(R) Distribution of OpenVINO(TM) Model Server software before version 2024.0 may allow an unauthenticaCVE-2024-320497.4BIG-IP Next Central Manager (CM) may allow an unauthenticated, remote attacker to obtain the BIG-IP Next LTM/WAF instance credentials.  NotCVE-2024-320516.5Insertion of sensitive information into log file issue exists in RoamWiFi R10 prior to 4.8.45. If this vulnerability is exploited, a networkCVE-2024-320539.8Hard-coded credentials are used by the  CyberPower PowerPanel platform to authenticate to the database, other services, and the cloud. TCVE-2024-320557.8A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past
CVE-2024-3204: Critical severity, CVSS 9.8 | Vulnix