CVE-2024-2850

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

A vulnerability was found in Tenda AC15 15.03.05.18 and classified as critical. Affected by this issue is the function saveParentControlInfo of the file /goform/saveParentControlInfo. The manipulation of the argument urls leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 24, 2024
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2024

CVE-2024-28519.8A vulnerability was found in Tenda AC15 15.03.05.18/15.03.20_multi. It has been classified as critical. This affects the function formSetSamCVE-2024-285159.8Buffer Overflow vulnerability in CSAPP_Lab CSAPP Lab3 15-213 Fall 20xx allows a remote attacker to execute arbitrary code via the lab3 of csCVE-2024-285197.8A kernel handle leak issue in ProcObsrvesx.sys 4.0.0.49 in MicroWorld Technologies Inc eScan Antivirus could allow privilege escalation for CVE-2024-28529.8A vulnerability was found in Tenda AC15 15.03.20_multi. It has been declared as critical. This vulnerability affects the function saveParentCVE-2024-285206.5File Upload vulnerability in Byzoro Networks Smart multi-service security gateway intelligent management platform version S210, allows an atCVE-2024-285217.8SQL Injection vulnerability in Netcome NS-ASG Application Security Gateway v.6.3.1 allows a local attacker to execute arbitrary code and obtCVE-2024-28539.8A vulnerability was found in Tenda AC10U 15.03.06.48/15.03.06.49. It has been rated as critical. This issue affects the function formSetSambCVE-2024-285359.8Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the mitInterface parameter of fromAddressNat function.CVE-2024-285379.8Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the page parameter of fromNatStaticSetting function.CVE-2024-28549.8A vulnerability classified as critical has been found in Tenda AC18 15.03.05.05. Affected is the function formSetSambaConf of the file /gofoCVE-2024-285459.8Tenda AC18 V15.03.05.05 contains a command injection vulnerablility in the deviceName parameter of formsetUsbUnload function.CVE-2024-285476.5Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the firewallEn parameter of formSetFirewallCfg function.
CVE-2024-2850: Critical severity, CVSS 9.8 | Vulnix