CVE-2024-21985

HighCVSS 7.6/10Last modified Jun 17, 2026

Description

ONTAP 9 versions prior to 9.9.1P18, 9.10.1P16, 9.11.1P13, 9.12.1P10 and 9.13.1P4 are susceptible to a vulnerability which could allow an authenticated user with multiple remote accounts with differing roles to perform actions via REST API beyond their intended privilege. Possible actions include viewing limited configuration details and metrics or modifying limited settings, some of which could result in a Denial of Service (DoS).

Metrics

CVSS 3.1 7.6/10CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jan 26, 2024
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2024

CVE-2024-219875.4SnapCenter versions 4.8 prior to 5.0 are susceptible to a vulnerability which could allow an authenticated SnapCenter Server user to modifCVE-2024-219885.3StorageGRID (formerly StorageGRID Webscale) versions prior to 11.7.0.9 and 11.8.0.5 are susceptible to disclosure of sensitive informationCVE-2024-219898.8ONTAP Select Deploy administration utility versions 9.12.1.x, 9.13.1.x and 9.14.1.x are susceptible to a vulnerability which when successfCVE-2024-21995.7A denial of service vulnerability was found in 389-ds-base ldap server. This issue may allow an authenticated user to cause a server crash wCVE-2024-219909.8ONTAP Select Deploy administration utility versions 9.12.1.x, 9.13.1.x and 9.14.1.x contain hard-coded credentials that could allow an attCVE-2024-219936.5SnapCenter versions prior to 5.0p1 are susceptible to a vulnerability which could allow an authenticated attacker to discover plaintext crCVE-2024-219944.3StorageGRID (formerly StorageGRID Webscale) versions prior to 11.9 are susceptible to a Denial of Service (DoS) vulnerability. Successful exCVE-2024-22006.1The Contact Form by BestWebSoft plugin for WordPress is vulnerable to Reflected Cross-Site Scripting via the ‘cntctfrm_contact_subject’ paraCVE-2024-220027.8CORSAIR iCUE 5.9.105 with iCUE Murals on Windows allows unprivileged users to insert DLL files in the cuepkg-1.2.6 subdirectory of the instaCVE-2024-220047.7Due to length check, an attacker with privilege access on a Linux Nonsecure operating system can trigger a vulnerability and leak the secureCVE-2024-220058.4there is a possible Authentication Bypass due to improperly used crypto. This could lead to local escalation of privilege with no additionalCVE-2024-220065.3OOB read in the TMU plugin that allows for memory disclosure in the power management subsystem of the device.
CVE-2024-21985: High severity, CVSS 7.6 | Vulnix