CVE-2024-0919

HighCVSS 7.2/10Last modified Jun 17, 2026

Description

A vulnerability was found in TRENDnet TEW-815DAP 1.0.2.0. It has been classified as critical. This affects the function do_setNTP of the component POST Request Handler. The manipulation of the argument NtpDstStart/NtpDstEnd leads to command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-252123. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

Metrics

CVSS 3.1 7.2/10CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jan 26, 2024
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2024

CVE-2024-09207.2A vulnerability was found in TRENDnet TEW-822DRE 1.03B02. It has been declared as critical. This vulnerability affects unknown code of the fCVE-2024-09219.8A vulnerability has been found in D-Link DIR-816 A2 1.10CNB04 and classified as critical. Affected by this vulnerability is an unknown functCVE-2024-09229.8A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this vulnerability is the function formCVE-2024-09239.8A vulnerability, which was classified as critical, has been found in Tenda AC10U 15.03.06.49_multi_TDE01. Affected by this issue is the funcCVE-2024-09249.8A vulnerability, which was classified as critical, was found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function formSetPPTPSeCVE-2024-09259.8A vulnerability has been found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This vulnerability affects the function foCVE-2024-09269.8A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This issue affects the function formWifiWpsOOB.CVE-2024-09279.8A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been classified as critical. Affected is the function fromAddressNaCVE-2024-09289.8A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been declared as critical. Affected by this vulnerability is the fuCVE-2024-09299.8A vulnerability was found in Tenda AC10U 15.03.06.49_multi_TDE01. It has been rated as critical. Affected by this issue is the function fromCVE-2024-09309.8A vulnerability classified as critical has been found in Tenda AC10U 15.03.06.49_multi_TDE01. This affects the function fromSetWirelessRepeaCVE-2024-09319.8A vulnerability classified as critical was found in Tenda AC10U 15.03.06.49_multi_TDE01. This vulnerability affects the function saveParentC
CVE-2024-0919: High severity, CVSS 7.2 | Vulnix