CVE-2023-50926

HighCVSS 7.5/10Last modified Jun 17, 2026

Description

Contiki-NG is an open-source, cross-platform operating system for Next-Generation IoT devices. An out-of-bounds read can be caused by an incoming DIO message when using the RPL-Lite implementation in the Contiki-NG operating system. More specifically, the prefix information of the DIO message contains a field that specifies the length of an IPv6 address prefix. The value of this field is not validated, which means that an attacker can set a value that is longer than the maximum prefix length. Subsequently, a memcmp function call that compares different prefixes can be called with a length argument that surpasses the boundary of the array allocated for the prefix, causing an out-of-bounds read. The problem has been patched in the "develop" branch of Contiki-NG, and is expected to be included in the next release. Users are advised to update as soon as they are able to or to manually apply the changes in Contiki-NG pull request #2721.

Metrics

CVSS 3.1 7.5/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 14, 2024
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2023

CVE-2023-509277.5Contiki-NG is an open-source, cross-platform operating system for Next-Generation IoT devices. An attacker can trigger out-of-bounds reads iCVE-2023-509289.0"Sandbox Accounts for Events" provides multiple, temporary AWS accounts to a number of authenticated users simultaneously via a browser-baseCVE-2023-509307.1An issue was discovered in savignano S/Notify before 4.0.2 for Jira. While an administrative user is logged on, the configuration settings oCVE-2023-509315.4An issue was discovered in savignano S/Notify before 2.0.1 for Bitbucket. While an administrative user is logged on, the configuration settiCVE-2023-509325.4An issue was discovered in savignano S/Notify before 4.0.2 for Confluence. While an administrative user is logged on, the configuration settCVE-2023-509336.1IBM PowerSC 1.3, 2.0, and 2.1 is vulnerable to HTML injection. A remote attacker could inject malicious HTML code, which when viewed, would CVE-2023-509345.3IBM PowerSC 1.3, 2.0, and 2.1 uses single-factor authentication which can lead to unnecessary risk of compromise when compared with the beneCVE-2023-509356.5IBM PowerSC 1.3, 2.0, and 2.1 fails to properly restrict access to a URL or resource, which may allow a remote attacker to obtain unauthorizCVE-2023-509368.8IBM PowerSC 1.3, 2.0, and 2.1 does not invalidate session after logout which could allow an authenticated user to impersonate another user oCVE-2023-509377.5IBM PowerSC 1.3, 2.0, and 2.1 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive inCVE-2023-509384.3IBM PowerSC 1.3, 2.0, and 2.1 could allow a remote attacker to hijack the clicking action of the victim. By persuading a victim to visit a mCVE-2023-509397.5IBM PowerSC 1.3, 2.0, and 2.1 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive in