CVE-2022-34398

HighCVSS 7.0/10Last modified Jun 17, 2026

Description

Dell BIOS contains a Time-of-check Time-of-use vulnerability. A local authenticated malicious user could\u00a0potentially exploit this vulnerability by using a specifically timed DMA transaction during an SMI to gain arbitrary code execution on the system.

Metrics

CVSS 3.1 7.0/10CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 1, 2023
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2022

CVE-2022-343992.3Dell Alienware m17 R5 BIOS version prior to 1.2.2 contain a buffer access vulnerability. A malicious user with admin privileges could potentCVE-2022-34406.1The Rock Convert WordPress plugin before 2.11.0 does not sanitise and escape an URL before outputting it back in an attribute when a specifiCVE-2022-344007.1Dell BIOS contains a heap buffer overflow vulnerability. A local attacker with admin privileges could potentially exploit this vulnerabilityCVE-2022-344017.5Dell BIOS contains a stack based buffer overflow vulnerability. A local authenticated malicious user may potentially exploit this vulnerabilCVE-2022-344024.9Dell Wyse ThinOS 2205 contains a Regular Expression Denial of Service Vulnerability in UI. An admin privilege attacker could potentially expCVE-2022-344038.8Dell BIOS contains a Stack based buffer overflow vulnerability. A local authenticated attacker could potentially exploit this vulnerability CVE-2022-344046.0Dell System Update, version 2.0.0 and earlier, contains an Improper Certificate Validation in data parser module. A local attacker with highCVE-2022-344057.3An improper access control vulnerability was identified in the Realtek audio driver. A local authenticated malicious user may potentially exCVE-2022-344066.7Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user CVE-2022-344076.7Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user CVE-2022-344086.7Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user CVE-2022-344096.7Dell PowerEdge BIOS and Dell Precision BIOS contain an Improper SMM communication buffer verification vulnerability. A local malicious user
CVE-2022-34398: High severity, CVSS 7.0 | Vulnix