Description
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.
Metrics
CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:HWeakness enumeration
Affected software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | SCALANCE X200-4P IRT | All versions < V5.5.2 |
| Siemens | SCALANCE X201-3P IRT | All versions < V5.5.2 |
| Siemens | SCALANCE X201-3P IRT PRO | All versions < V5.5.2 |
| Siemens | SCALANCE X202-2IRT | All versions < V5.5.2 |
| Siemens | SCALANCE X202-2IRT | All versions < V5.5.2 |
| Siemens | SCALANCE X202-2P IRT | All versions < V5.5.2 |
| Siemens | SCALANCE X202-2P IRT PRO | All versions < V5.5.2 |
| Siemens | SCALANCE X204-2 | All versions < V5.2.6 |
| Siemens | SCALANCE X204-2FM | All versions < V5.2.6 |
| Siemens | SCALANCE X204-2LD | All versions < V5.2.6 |
| Siemens | SCALANCE X204-2LD TS | All versions < V5.2.6 |
| Siemens | SCALANCE X204-2TS | All versions < V5.2.6 |
| Siemens | SCALANCE X204IRT | All versions < V5.5.2 |
| Siemens | SCALANCE X204IRT | All versions < V5.5.2 |
| Siemens | SCALANCE X204IRT PRO | All versions < V5.5.2 |
| Siemens | SCALANCE X206-1 | All versions < V5.2.6 |
| Siemens | SCALANCE X206-1LD | All versions < V5.2.6 |
| Siemens | SCALANCE X208 | All versions < V5.2.6 |
| Siemens | SCALANCE X208PRO | All versions < V5.2.6 |
| Siemens | SCALANCE X212-2 | All versions < V5.2.6 |
| Siemens | SCALANCE X212-2LD | All versions < V5.2.6 |
| Siemens | SCALANCE X216 | All versions < V5.2.6 |
| Siemens | SCALANCE X224 | All versions < V5.2.6 |
| Siemens | SCALANCE XF201-3P IRT | All versions < V5.5.2 |
| Siemens | SCALANCE XF202-2P IRT | All versions < V5.5.2 |
| Siemens | SCALANCE XF204 | All versions < V5.2.6 |
| Siemens | SCALANCE XF204-2 | All versions < V5.2.6 |
| Siemens | SCALANCE XF204-2BA IRT | All versions < V5.5.2 |
| Siemens | SCALANCE XF204IRT | All versions < V5.5.2 |
| Siemens | SCALANCE XF206-1 | All versions < V5.2.6 |
| Siemens | SCALANCE XF208 | All versions < V5.2.6 |
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdfPatch, Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-310038.pdfPatch, Vendor Advisory
Timeline
- Published
- Jul 12, 2022
- Last modified
- Jun 17, 2026
- NVD status
- Modified