CVE-2022-20467

MediumCVSS 5.5/10Last modified Jun 17, 2026

Description

In isBluetoothShareUri of BluetoothOppUtility.java, there is a possible incorrect file read due to a confused deputy. This could lead to local information disclosure with no additional execution privileges needed. User interaction is needed for exploitation.Product: AndroidVersions: Android-11 Android-12 Android-12L Android-13Android ID: A-225880741

Metrics

CVSS 3.1 5.5/10CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N

Affected software

No affected versions have been published.

Timeline

Published
Mar 24, 2023
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2022

CVE-2022-204686.5In BNEP_ConnectResp of bnep_api.cc, there is a possible out of bounds read due to an incorrect bounds check. This could lead to local informCVE-2022-204698.8In avct_lcb_msg_asmbl of avct_lcb_act.cc, there is a possible out of bounds write due to a missing bounds check. This could lead to local esCVE-2022-20472.7In Eclipse Jetty versions 9.4.0 thru 9.4.46, and 10.0.0 thru 10.0.9, and 11.0.0 thru 11.0.9 versions, the parsing of the authority segment oCVE-2022-204707.8In bindRemoteViewsService of AppWidgetServiceImpl.java, there is a possible way to bypass background activity launch due to improper input vCVE-2022-204715.5In SendIncDecRestoreCmdPart2 of NxpMfcReader.cc, there is a possible out of bounds read due to a missing bounds check. This could lead to loCVE-2022-204729.8In toLanguageTag of LocaleListCache.cpp, there is a possible out of bounds read due to an incorrect bounds check. This could lead to remote CVE-2022-204739.8In toLanguageTag of LocaleListCache.cpp, there is a possible out of bounds read due to an incorrect bounds check. This could lead to remote CVE-2022-204747.8In readLazyValue of Parcel.java, there is a possible loading of arbitrary code into the System Settings app due to a confused deputy. This cCVE-2022-204757.8In test of ResetTargetTaskHelper.java, there is a possible hijacking of any app which sets allowTaskReparenting="true" due to a confused depCVE-2022-204765.5In setEnabledSetting of PackageManager.java, there is a possible way to get the device into an infinite reboot loop due to resource exhaustiCVE-2022-204777.8In shouldHideNotification of KeyguardNotificationVisibilityProvider.kt, there is a possible way to show hidden notifications due to a logic CVE-2022-204787.8In NotificationChannel of NotificationChannel.java, there is a possible failure to persist permissions settings due to resource exhaustion.
CVE-2022-20467: Medium severity, CVSS 5.5 | Vulnix