Description

A deserialization vulnerability exists in how the AosService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier verifies serialized data. This vulnerability may allow a remote, unauthenticated attacker to execute arbitrary commands in FactoryTalk AssetCentre.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Mar 23, 2022
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2021

CVE-2021-274635.3A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications utilize persistenCVE-2021-274649.8The ArchiveService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier exposes functions lacking proper authenticaCVE-2021-274656.1A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications do not validate wCVE-2021-274669.8A deserialization vulnerability exists in how the ArchiveService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earliCVE-2021-274676.1A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected product’s web interface allowsCVE-2021-274689.8The AosService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier exposes functions lacking proper authenticationCVE-2021-274709.8A deserialization vulnerability exists in how the LogService.rem service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier vCVE-2021-274718.6The parsing mechanism that processes certain file types does not provide input sanitization for file paths. This may allow an attacker to crCVE-2021-274729.8A vulnerability exists in the RunSearch function of SearchService service in Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier,CVE-2021-274738.2Rockwell Automation Connected Components Workbench v12.00.00 and prior does not sanitize paths specified within the .ccwarc archive file durCVE-2021-274747.5Rockwell Automation FactoryTalk AssetCentre v10.00 and earlier does not properly restrict all functions relating to IIS remoting services. TCVE-2021-274758.6Rockwell Automation Connected Components Workbench v12.00.00 and prior does not limit the objects that can be deserialized. This vulnerabili
CVE-2021-27462: Critical severity, CVSS 9.8 | Vulnix