CVE-2020-8144

HighCVSS 8.4/10Last modified Jun 17, 2026

Description

The UniFi Video Server v3.9.3 and prior (for Windows 7/8/10 x64) web interface Firmware Update functionality, under certain circumstances, does not validate firmware download destinations to ensure they are within the intended destination directory tree. It accepts a request with a URL to firmware update information. If the version field contains ..\ character sequences, the destination file path to save the firmware can be manipulated to be outside the intended destination directory tree. Fixed in UniFi Video Controller v3.10.3 and newer.

Metrics

CVSS 3.1 8.4/10CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 1, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-81456.5The UniFi Video Server (Windows) web interface configuration restore functionality at the “backup” and “wizard” endpoints does not implementCVE-2020-81467.8In UniFi Video v3.10.1 (for Windows 7/8/10 x64) there is a Local Privileges Escalation to SYSTEM from arbitrary file deletion and DLL hijackCVE-2020-81479.8Flaw in input validation in npm package utils-extend version 1.0.8 and earlier may allow prototype pollution attack that may result in remotCVE-2020-81485.3UniFi Cloud Key firmware < 1.1.6 contains a vulnerability that enables an attacker being able to change a device hostname by sending a malicCVE-2020-81499.8Lack of output sanitization allowed an attack to execute arbitrary shell commands via the logkitty npm package before version 0.7.1.CVE-2020-81504.1A cryptographic issue in Nextcloud Server 19.0.1 allowed an attacker to downgrade the encryption scheme and break the integrity of encryptedCVE-2020-81517.5There is a possible information disclosure issue in Active Resource <v5.1.1 that could allow an attacker to create specially crafted requestCVE-2020-81524.4Insufficient protection of the server-side encryption keys in Nextcloud Server 19.0.1 allowed an attacker to replace the public key to decryCVE-2020-81538.1Improper access control in Groupfolders app 4.0.3 allowed to delete hidden directories when when renaming an accessible item to the same namCVE-2020-81547.7An Insecure direct object reference vulnerability in Nextcloud Server 18.0.2 allowed an attacker to remote wipe devices of other users when CVE-2020-81555.4An outdated 3rd party library in the Files PDF viewer for Nextcloud Server 18.0.2 caused a Cross-site scripting vulnerability when opening aCVE-2020-81567.0A missing verification of the TLS host in Nextcloud Mail 1.1.3 allowed a man in the middle attack.
CVE-2020-8144: High severity, CVSS 8.4 | Vulnix