CVE-2020-7131

CriticalCVSS 9.0/10Last modified Jun 17, 2026

Description

This document describes a security vulnerability in Blade Maintenance Entity, Integrated Maintenance Entity and Maintenance Entity products. All J/H-series NonStop systems have a security vulnerability associated with an open UDP port 17185 on the Maintenance LAN which could result in information disclosure, denial-of-service attacks or local memory corruption against the affected system and a complete control of the system may also be possible. This vulnerability exists only if one gains access to the Maintenance LAN to which Blade Maintenance Entity, Integrated Maintenance Entity or Maintenance Entity product is connected. **Workaround:** Block the UDP port 17185(In the Maintenance LAN Network Switch/Firewall). Fix: Install following SPRs, which are already available: * T1805A01^AAI (Integrated Maintenance Entity) * T4805A01^AAZ (Blade Maintenance Entity). These SPRs are also usable with the following RVUs: * J06.19.00 ? J06.23.01. No fix planned for the following RVUs: J06.04.00 ? J06.18.01. No fix planned for H-Series NonStop systems. No fix planned for the product T2805 (Maintenance Entity).

Metrics

CVSS 3.1 9.0/10CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 24, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-71325.4A potential security vulnerability has been identified in HPE Onboard Administrator. The vulnerability could be remotely exploited to allow CVE-2020-71339.8A unauthorized remote access vulnerability was discovered in HPE IOT + GCP version(s): 1.4.0, 1.4.1, 1.4.2, 1.2.4.2.CVE-2020-71346.5A remote access to sensitive data vulnerability was discovered in HPE IOT + GCP version(s): 1.4.0, 1.4.1, 1.4.2, 1.2.4.2.CVE-2020-71357.8A potential security vulnerability has been identified in the disk drive firmware installers named Supplemental Update / Online ROM Flash CoCVE-2020-71369.8A security vulnerability in HPE Smart Update Manager (SUM) prior to version 8.5.6 could allow remote unauthorized access. Hewlett Packard EnCVE-2020-71376.7A validation issue in HPE Superdome Flex's RMC component may allow local elevation of privilege. Apply HPE Superdome Flex Server version 3.2CVE-2020-71388.8Potential remote code execution security vulnerabilities have been identified with HPE Nimble Storage systems that could be exploited by an CVE-2020-71398.1Potential remote access security vulnerabilities have been identified with HPE Nimble Storage systems that could be exploited by an attackerCVE-2020-71406.1A security vulnerability in HPE IceWall SSO Dfw and Dgfw (Domain Gateway Option) could be exploited remotely to cause a remote cross-site scCVE-2020-71419.8A adddevicetoview expression language injection remote code execution vulnerability was discovered in HPE Intelligent Management Center (iMCCVE-2020-71429.8A eventinfo_content expression language injection remote code execution vulnerability was discovered in HPE Intelligent Management Center (iCVE-2020-71439.8A faultdevparasset expression language injection remote code execution vulnerability was discovered in HPE Intelligent Management Center (iM
CVE-2020-7131: Critical severity, CVSS 9.0 | Vulnix