Description
Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial of service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device.
Metrics
CVSS 3.1 7.5/10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HWeakness enumeration
Affected software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller | < * |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 | < * |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P | < V4.7 |
| Siemens | RUGGEDCOM RM1224 LTE(4G) EU | < V6.4 |
| Siemens | RUGGEDCOM RM1224 LTE(4G) NAM | < V6.4 |
| Siemens | SCALANCE M804PB | < V6.4 |
| Siemens | SCALANCE M812-1 ADSL-Router | < V6.4 |
| Siemens | SCALANCE M812-1 ADSL-Router | < V6.4 |
| Siemens | SCALANCE M816-1 ADSL-Router | < V6.4 |
| Siemens | SCALANCE M816-1 ADSL-Router | < V6.4 |
| Siemens | SCALANCE M826-2 SHDSL-Router | < V6.4 |
| Siemens | SCALANCE M874-2 | < V6.4 |
| Siemens | SCALANCE M874-3 | < V6.4 |
| Siemens | SCALANCE M874-3 3G-Router (CN) | < V6.4 |
| Siemens | SCALANCE M876-3 | < V6.4 |
| Siemens | SCALANCE M876-3 (ROK) | < V6.4 |
| Siemens | SCALANCE M876-4 | < V6.4 |
| Siemens | SCALANCE M876-4 (EU) | < V6.4 |
| Siemens | SCALANCE M876-4 (NAM) | < V6.4 |
| Siemens | SCALANCE MUM853-1 (A1) | < V6.4 |
| Siemens | SCALANCE MUM853-1 (B1) | < V6.4 |
| Siemens | SCALANCE MUM853-1 (EU) | < V6.4 |
| Siemens | SCALANCE MUM856-1 (A1) | < V6.4 |
| Siemens | SCALANCE MUM856-1 (B1) | < V6.4 |
| Siemens | SCALANCE MUM856-1 (CN) | < V6.4 |
| Siemens | SCALANCE MUM856-1 (EU) | < V6.4 |
| Siemens | SCALANCE MUM856-1 (RoW) | < V6.4 |
| Siemens | SCALANCE S615 EEC LAN-Router | < V6.4 |
| Siemens | SCALANCE S615 LAN-Router | < V6.4 |
| Siemens | SCALANCE W1748-1 M12 | < V3.0.0 |
| Siemens | SCALANCE W1748-1 M12 | < V3.0.0 |
| Siemens | SCALANCE W1788-1 M12 | < V3.0.0 |
| Siemens | SCALANCE W1788-2 EEC M12 | < V3.0.0 |
| Siemens | SCALANCE W1788-2 M12 | < V3.0.0 |
| Siemens | SCALANCE W1788-2IA M12 | < V3.0.0 |
| Siemens | SCALANCE W721-1 RJ45 | < V6.4.0 |
| Siemens | SCALANCE W721-1 RJ45 | < V6.4.0 |
| Siemens | SCALANCE W722-1 RJ45 | < V6.4.0 |
| Siemens | SCALANCE W722-1 RJ45 | < V6.4.0 |
| Siemens | SCALANCE W722-1 RJ45 | < V6.4.0 |
| Siemens | SCALANCE W734-1 RJ45 | < V6.4.0 |
| Siemens | SCALANCE W734-1 RJ45 | < V6.4.0 |
| Siemens | SCALANCE W734-1 RJ45 | < V6.4.0 |
| Siemens | SCALANCE W734-1 RJ45 (USA) | < V6.4.0 |
| Siemens | SCALANCE W738-1 M12 | < V6.4.0 |
| Siemens | SCALANCE W738-1 M12 | < V6.4.0 |
| Siemens | SCALANCE W748-1 M12 | < V6.4.0 |
| Siemens | SCALANCE W748-1 M12 | < V6.4.0 |
| Siemens | SCALANCE W748-1 RJ45 | < V6.4.0 |
| Siemens | SCALANCE W748-1 RJ45 | < V6.4.0 |
References
- https://cert-portal.siemens.com/productcert/html/ssa-599968.html
- https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdfPatch, Vendor Advisory
- https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03Third Party Advisory, US Government Resource
- https://cert-portal.siemens.com/productcert/html/ssa-599968.html
- https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdfPatch, Vendor Advisory
- https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03Third Party Advisory, US Government Resource
Timeline
- Published
- Jul 13, 2021
- Last modified
- Jun 17, 2026
- NVD status
- Modified