CVE-2020-24676

HighCVSS 7.8/10Last modified Jun 17, 2026

Description

In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as.

Metrics

CVSS 3.1 7.8/10CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Dec 22, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-246778.8Vulnerabilities in the S+ Operations and S+ Historian web applications can lead to a possible code execution and privilege escalation, redirCVE-2020-246788.8An authenticated user might execute malicious code under the user context and take control of the system. S+ Operations or S+ Historian dataCVE-2020-246799.8A S+ Operations and S+ Historian service is subject to a DoS by special crafted messages. An attacker might use this flaw to make it crash oCVE-2020-246807.0In S+ Operations and S+ Historian, the passwords of internal users (not Windows Users) are encrypted but improperly stored in a database.CVE-2020-246818.8Incorrect Permission Assignment for Critical Resource vulnerability in B&R Industrial Automation Automation Studio allows Privilege EscalatiCVE-2020-246827.8Unquoted Search Path or Element vulnerability in B&R Industrial Automation Automation Studio, B&R Industrial Automation NET/PVI allows TargeCVE-2020-246839.8The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at CVE-2020-246858.6An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service (DoS) vulnerability. VulneraCVE-2020-246867.5The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users lCVE-2020-246927.1The Ignite portal in Mitel MiContact Center Business before 9.3.0.0 could allow an attacker to execute arbitrary scripts due to insufficientCVE-2020-246933.3The Ignite portal in Mitel MiContact Center Business before 9.3.0.0 could allow a local attacker to view system information due to insufficiCVE-2020-246968.1An issue was discovered in PowerDNS Authoritative through 4.3.0 when --enable-experimental-gss-tsig is used. A remote, unauthenticated attac
CVE-2020-24676: High severity, CVSS 7.8 | Vulnix