CVE-2020-16228

MediumCVSS 6.4/10Last modified Jun 17, 2026

Description

In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.

Metrics

CVSS 3.1 6.4/10CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Sep 11, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-162297.8Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user CVE-2020-16235.5A local, authenticated user with shell can view sensitive configuration information via the ev.ops configuration file. This issue affects alCVE-2020-162302.3All version of Ewon Flexy and Cosy prior to 14.1 use wildcards such as (*) under which domains can request resources. An attacker with localCVE-2020-162318.8The affected Bachmann Electronic M-Base Controllers of version MSYS v1.06.14 and later use weak cryptography to protect device passwords. AfCVE-2020-162329.8In Yokogawa WideField3 R1.01 - R4.03, a buffer overflow could be caused when a user loads a maliciously crafted project file.CVE-2020-162337.5An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data fCVE-2020-162347.8In PLC WinProladder Version 3.28 and prior, a stack-based buffer overflow vulnerability can be exploited when a valid user opens a speciallyCVE-2020-162356.5Inadequate encryption may allow the credentials used by Emerson OpenEnterprise, up through version 3.3.5, to access field devices and externCVE-2020-162367.8FPWIN Pro is vulnerable to an out-of-bounds read vulnerability when a user opens a maliciously crafted project file, which may allow an attaCVE-2020-162372.1Philips SureSigns VS4, A.07.107 and prior receives input or data, but it does not validate or incorrectly validates that the input has the pCVE-2020-162386.7A vulnerability in the configuration import mechanism of the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data moduleCVE-2020-162394.9When an actor claims to have a given identity, Philips SureSigns VS4, A.07.107 and prior does not prove or insufficiently proves the clai
CVE-2020-16228: Medium severity, CVSS 6.4 | Vulnix