Description

The default installation path of the TwinCAT XAR 3.1 software in all versions is underneath C:\TwinCAT. If the directory does not exist it and further subdirectories are created with permissions which allow every local user to modify the content. The default installation registers TcSysUI.exe for automatic execution upon log in of a user. If a less privileged user has a local account he or she can replace TcSysUI.exe. It will be executed automatically by another user during login. This is also true for users with administrative access. Consequently, a less privileged user can trick a higher privileged user into executing code he or she modified this way. By default Beckhoff’s IPCs are shipped with TwinCAT software installed this way and with just a single local user configured. Thus the vulnerability exists if further less privileged users have been added.

Metrics

CVSS 3.1 7.3/10CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Nov 19, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-125118.8Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to a Cross-Site Request Forgery (CSRF) in the web interface.CVE-2020-125125.4Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to an authenticated reflected POST Cross-Site ScriptingCVE-2020-125138.8Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to an authenticated blind OS Command Injection.CVE-2020-125144.9Pepperl+Fuchs Comtrol IO-Link Master in Version 1.5.48 and below is prone to a NULL Pointer Dereference that leads to a DoS in discoverydCVE-2020-125167.5Older firmware versions (FW1 up to FW10) of the WAGO PLC family 750-88x and 750-352 are vulnerable for a special denial of service attack.CVE-2020-125179.0On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an authenticated low privileged user could embed malicious Javascript CVE-2020-125185.5On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use the knowledge gained by reading the insufficientlyCVE-2020-125199.8On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use this vulnerability i.e. to open a reverse shell wiCVE-2020-12527.8<p>A remote code execution vulnerability exists when Windows improperly handles objects in memory. To exploit the vulnerability an attacker CVE-2020-125216.5On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the CVE-2020-125229.8The reported vulnerability allows an attacker who has network access to the device to execute code with specially crafted packets in WAGO SeCVE-2020-125239.1On Phoenix Contact mGuard Devices versions before 8.8.3 LAN ports get functional after reboot even if they are disabled in the device config
CVE-2020-12510: High severity, CVSS 7.3 | Vulnix