CVE-2020-10610

HighCVSS 7.8/10Last modified Jun 17, 2026

Description

In OSIsoft PI System multiple products and versions, a local attacker can modify a search path and plant a binary to exploit the affected PI System software to take control of the local computer at Windows system privilege level, resulting in unauthorized information disclosure, deletion, or modification.

Metrics

CVSS 3.1 7.8/10CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jul 24, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-106119.8Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary codCVE-2020-106129.1Opto 22 SoftPAC Project Version 9.6 and prior. SoftPACAgent communicates with SoftPACMonitor over network Port 22000. However, this port is CVE-2020-106137.5Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive inCVE-2020-106144.8In OSIsoft PI System multiple products and versions, an authenticated remote attacker with write access to PI Vision databases could inject CVE-2020-106157.5Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-servicCVE-2020-106168.8Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC does not specify the path of multiple imported .dll files. Therefore, an attacker canCVE-2020-106177.5There are multiple ways an unauthenticated attacker could perform SQL injection on WebAccess/NMS (versions prior to 3.0.2) to gain access toCVE-2020-106185.5LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users.CVE-2020-106199.1An attacker could use a specially crafted URL to delete files outside the WebAccess/NMS's (versions prior to 3.0.2) control.CVE-2020-10627.5A remote code execution vulnerability exists when Internet Explorer improperly accesses objects in memory. The vulnerability could corrupt mCVE-2020-106209.8Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC communication does not include any credentials. This allows an attacker with network CVE-2020-106219.8Multiple issues exist that allow files to be uploaded and executed on the WebAccess/NMS (versions prior to 3.0.2).
CVE-2020-10610: High severity, CVSS 7.8 | Vulnix