Description

Universal Robots Robot Controllers Version CB2 SW Version 1.4 upwards, CB3 SW Version 3.0 and upwards, e-series SW Version 5.0 and upwards expose a service called DashBoard server at port 29999 that allows for control over core robot functions like starting/stopping programs, shutdown, reset safety and more. The DashBoard server is not protected by any kind of authentication or authorization.

Metrics

CVSS 3.1 9.4/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 6, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2020

CVE-2020-102668.1UR+ (Universal Robots+) is a platform of hardware and software component sellers, for Universal Robots robots. When installing any of these CVE-2020-102677.5Universal Robots control box CB 3.1 across firmware versions (tested on 1.12.1, 1.12, 1.11 and 1.10) does not encrypt or protect in any way CVE-2020-102686.1Critical services for operation can be terminated from windows task manager, bringing the manipulator to a halt. After this a Re-CalibrationCVE-2020-102699.8One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured inCVE-2020-10277.8An elevation of privilege vulnerability exists in the way that the Windows Kernel handles objects in memory, aka 'Windows Kernel Elevation oCVE-2020-102709.8Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control DaCVE-2020-102719.8MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network inCVE-2020-102729.8MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph without any sort CVE-2020-102737.5MiR controllers across firmware versions 2.8.1.1 and before do not encrypt or protect in any way the intellectual property artifacts installCVE-2020-102747.1The access tokens for the REST API are directly derived (sha256 and base64 encoding) from the publicly available default credentials from thCVE-2020-102759.8The access tokens for the REST API are directly derived from the publicly available default credentials for the web interface. Given a USERNCVE-2020-102769.8The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to
CVE-2020-10265: Critical severity, CVSS 9.4 | Vulnix