Description
The monitor barrier of the affected products insufficiently blocks data from being forwarded over the mirror port into the mirrored network. An attacker could use this behavior to transmit malicious packets to systems in the mirrored network, possibly influencing their configuration and runtime behavior.
Metrics
CVSS 3.1 9.1/10
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:HWeakness enumeration
Affected software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | SCALANCE X204-2 | All versions < V5.2.6 |
| Siemens | SCALANCE X204-2FM | All versions < V5.2.6 |
| Siemens | SCALANCE X204-2LD | All versions < V5.2.6 |
| Siemens | SCALANCE X204-2LD TS | All versions < V5.2.6 |
| Siemens | SCALANCE X204-2TS | All versions < V5.2.6 |
| Siemens | SCALANCE X206-1 | All versions < V5.2.6 |
| Siemens | SCALANCE X206-1LD | All versions < V5.2.6 |
| Siemens | SCALANCE X208 | All versions < V5.2.6 |
| Siemens | SCALANCE X208PRO | All versions < V5.2.6 |
| Siemens | SCALANCE X212-2 | All versions < V5.2.6 |
| Siemens | SCALANCE X212-2LD | All versions < V5.2.6 |
| Siemens | SCALANCE X216 | All versions < V5.2.6 |
| Siemens | SCALANCE X224 | All versions < V5.2.6 |
| Siemens | SCALANCE X302-7 EEC (230V) | All versions < V4.1.3 |
| Siemens | SCALANCE X302-7 EEC (230V, coated) | All versions < V4.1.3 |
| Siemens | SCALANCE X302-7 EEC (24V) | All versions < V4.1.3 |
| Siemens | SCALANCE X302-7 EEC (24V, coated) | All versions < V4.1.3 |
| Siemens | SCALANCE X302-7 EEC (2x 230V) | All versions < V4.1.3 |
| Siemens | SCALANCE X302-7 EEC (2x 230V, coated) | All versions < V4.1.3 |
| Siemens | SCALANCE X302-7 EEC (2x 24V) | All versions < V4.1.3 |
| Siemens | SCALANCE X302-7 EEC (2x 24V, coated) | All versions < V4.1.3 |
| Siemens | SCALANCE X304-2FE | All versions < V4.1.3 |
| Siemens | SCALANCE X306-1LD FE | All versions < V4.1.3 |
| Siemens | SCALANCE X307-2 EEC (230V) | All versions < V4.1.3 |
| Siemens | SCALANCE X307-2 EEC (230V, coated) | All versions < V4.1.3 |
| Siemens | SCALANCE X307-2 EEC (24V) | All versions < V4.1.3 |
| Siemens | SCALANCE X307-2 EEC (24V, coated) | All versions < V4.1.3 |
| Siemens | SCALANCE X307-2 EEC (2x 230V) | All versions < V4.1.3 |
| Siemens | SCALANCE X307-2 EEC (2x 230V, coated) | All versions < V4.1.3 |
| Siemens | SCALANCE X307-2 EEC (2x 24V) | All versions < V4.1.3 |
| Siemens | SCALANCE X307-2 EEC (2x 24V, coated) | All versions < V4.1.3 |
| Siemens | SCALANCE X307-3 | All versions < V4.1.3 |
| Siemens | SCALANCE X307-3 | All versions < V4.1.3 |
| Siemens | SCALANCE X307-3LD | All versions < V4.1.3 |
| Siemens | SCALANCE X307-3LD | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2 | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2 | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2LD | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2LD | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2LH | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2LH | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2LH+ | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2LH+ | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2M | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2M | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2M PoE | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2M PoE | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2M TS | All versions < V4.1.3 |
| Siemens | SCALANCE X308-2M TS | All versions < V4.1.3 |
| Siemens | SCALANCE X310 | All versions < V4.1.3 |
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdfPatch, Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-557804.pdfPatch, Vendor Advisory
Timeline
- Published
- Mar 26, 2019
- Last modified
- Jun 17, 2026
- NVD status
- Modified