CVE-2019-3931

HighCVSS 8.8/10Last modified Jun 17, 2026

Description

Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to argumention injection to the curl binary via crafted HTTP requests to return.cgi. A remote, authenticated attacker can use this vulnerability to upload files to the device and ultimately execute code as root.

Metrics

CVSS 3.1 8.8/10CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 30, 2019
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2019

CVE-2019-39329.8Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 are vulnerable to authentication bypass due to a hard-coded password CVE-2019-39335.3Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code simply by requesting /iCVE-2019-39345.3Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to bypass the presentation code sending a crafted HTTP CVE-2019-39359.1Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 allows anyone to act as a moderator to a slide show via crafted HTTP CVE-2019-39367.5Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 is vulnerable to denial of service via a crafted request to TCP port CVE-2019-39377.8Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuratCVE-2019-39387.8Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, and other configuration options in the fCVE-2019-39399.8Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 use default credentials admin/admin and moderator/moderator for the wCVE-2019-39409.8Advantech WebAccess 8.3.4 is vulnerable to file upload attacks via unauthenticated RPC call. An unauthenticated, remote attacker can use thiCVE-2019-39417.5Advantech WebAccess 8.3.4 allows unauthenticated, remote attackers to delete arbitrary files via IOCTL 10005 RPC.CVE-2019-39427.5Advantech WebAccess 8.3.4 does not properly restrict an RPC call that allows unauthenticated, remote users to read files. An attacker can usCVE-2019-39438.1MikroTik RouterOS versions Stable 6.43.12 and below, Long-term 6.42.12 and below, and Testing 6.44beta75 and below are vulnerable to an auth
CVE-2019-3931: High severity, CVSS 8.8 | Vulnix