CVE-2019-25708

LowCVSS 3.5/10Last modified Jun 17, 2026

Description

Heatmiser Wifi Thermostat 1.7 contains a cross-site request forgery vulnerability that allows attackers to change administrator credentials by tricking authenticated users into submitting malicious requests. Attackers can craft HTML forms targeting the networkSetup.htm endpoint with parameters usnm, usps, and cfps to modify the admin username and password without user consent.

Metrics

CVSS 3.1 3.5/10CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Apr 12, 2026
Last modified
Jun 17, 2026
NVD status
Analyzed

Related CVEs from 2019

CVE-2019-257099.8CF Image Hosting Script 1.6.5 allows unauthenticated attackers to download and decode the application database by accessing the imgdb.db filCVE-2019-25716.6Vulnerability in the RDBMS DataPump component of Oracle Database Server. Supported versions that are affected are 11.2.0.4, 12.1.0.2, 12.2.0CVE-2019-257109.1Dolibarr ERP-CRM 8.0.4 contains an SQL injection vulnerability in the rowid parameter of the admin dict.php endpoint that allows attackers tCVE-2019-257115.5SpotFTP Password Recover 2.4.2 contains a denial of service vulnerability that allows local attackers to crash the application by supplying CVE-2019-257125.5BlueAuditor 1.7.2.0 contains a buffer overflow vulnerability in the registration key field that allows local attackers to crash the applicatCVE-2019-257138.1MyT-PM 1.5.1 contains an SQL injection vulnerability that allows authenticated attackers to execute arbitrary SQL queries by injecting malicCVE-2019-257149.3Seeyon OA A8 contains an unauthenticated arbitrary file write vulnerability in the /seeyon/htmlofficeservlet endpoint that allows remote attCVE-2019-257167.5Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain a denial-of-service vulnerability that allows remote attackers to cause CVE-2019-257174.3Dräger Infinity Delta, Delta XL, and Kappa patient monitors contain an information disclosure vulnerability that allows unauthenticated netwCVE-2019-257187.8Dräger Infinity Explorer C700 contains a privilege escalation vulnerability that allows attackers to break out of kiosk mode and access the CVE-2019-257198.6Dräger Infinity Acute Care System and Standalone Infinity M540 patient monitors running software versions VG4.1.1, VG4.0.3, and lower contaiCVE-2019-25725.3Vulnerability in the Oracle SOA Suite component of Oracle Fusion Middleware (subcomponent: Fabric Layer). The supported version that is affe