Description

A partial authentication bypass vulnerability exists on Realtek RTL8812AR 1.21WW, RTL8196D 1.0.0, RTL8192ER 2.10, and RTL8881AN 1.09 devices. The vulnerability allows sending an unencrypted data frame to a WPA2-protected WLAN router where the packet is routed through the network. If successful, a response is sent back as an encrypted frame, which would allow an attacker to discern information or potentially modify data.

Metrics

CVSS 3.1 5.4/10CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Sep 30, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2019

CVE-2019-189915.4A partial authentication bypass vulnerability exists on Atheros AR9132 3.60(AMX.8), AR9283 1.85, and AR9285 1.0.0.12NA devices. The vulnerabCVE-2019-189925.4OpenWrt 18.06.4 allows XSS via these Name fields to the cgi-bin/luci/admin/network/firewall/rules URI: "Open ports on router" and "New forwaCVE-2019-189935.4OpenWrt 18.06.4 allows XSS via the "New port forward" Name field to the cgi-bin/luci/admin/network/firewall/forwards URI (this can occur, foCVE-2019-189946.5Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when tryinCVE-2019-189955.3The HMISimulator component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier fails to validate the content-length field for HTTPCVE-2019-189967.8Path settings in HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier accept DLLs outside of the program directCVE-2019-189977.5The HMISimulator component of ABB PB610 Panel Builder 600 uses the readFile/writeFile interface to manipulate the work file. Path configuratCVE-2019-189987.1Insufficient access control in the web interface of ABB Asset Suite versions 9.0 to 9.3, 9.4 prior to 9.4.2.6, 9.5 prior to 9.5.3.2 and 9.6.CVE-2019-19007.5A vulnerability in the web server of Cisco Integrated Management Controller (IMC) could allow an unauthenticated, remote attacker to cause tCVE-2019-190006.5For ABB eSOMS 4.0 to 6.0.3, the Cache-Control and Pragma HTTP header(s) have not been properly configured within the application response. TCVE-2019-190016.5For ABB eSOMS versions 4.0 to 6.0.2, the X-Frame-Options header is not configured in HTTP response. This can potentially allow 'ClickJackingCVE-2019-190025.4For ABB eSOMS versions 4.0 to 6.0.2, the X-XSS-Protection HTTP response header is not set in responses from the web server. For older web br
CVE-2019-18990: Medium severity, CVSS 5.4 | Vulnix