Description
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack.
The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device.
Metrics
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:HWeakness enumeration
Affected software
| Vendor | Product | Versions |
|---|---|---|
| Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller | < * |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 | All Versions < V4.5 |
| Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P | All Versions < V4.6 |
| Siemens | PROFINET Driver for Controller | All Versions < V2.1 |
| Siemens | RUGGEDCOM RM1224 family | All versions < V4.3 |
| Siemens | SCALANCE M804PB | All versions < V4.3 |
| Siemens | SCALANCE M812-1 ADSL-Router | All versions < V4.3 |
| Siemens | SCALANCE M812-1 ADSL-Router | All versions < V4.3 |
| Siemens | SCALANCE M816-1 ADSL-Router | All versions < V4.3 |
| Siemens | SCALANCE M816-1 ADSL-Router | All versions < V4.3 |
| Siemens | SCALANCE M826-2 SHDSL-Router | All versions < V4.3 |
| Siemens | SCALANCE M874-2 | All versions < V4.3 |
| Siemens | SCALANCE M874-3 | All versions < V4.3 |
| Siemens | SCALANCE M876-3 | All versions < V4.3 |
| Siemens | SCALANCE M876-3 (ROK) | All versions < V4.3 |
| Siemens | SCALANCE M876-4 (EU) | All versions < V4.3 |
| Siemens | SCALANCE M876-4 (NAM) | All versions < V4.3 |
| Siemens | SCALANCE S615 LAN-Router | All versions < V4.3 |
| Siemens | SCALANCE W-700 IEEE 802.11n family | All versions <= V6.0.1 |
| Siemens | SCALANCE X200-4P IRT | All Versions < V5.3 |
| Siemens | SCALANCE X201-3P IRT | All Versions < V5.3 |
| Siemens | SCALANCE X201-3P IRT PRO | All Versions < V5.3 |
| Siemens | SCALANCE X202-2IRT | All Versions < V5.3 |
| Siemens | SCALANCE X202-2P IRT | All Versions < V5.3 |
| Siemens | SCALANCE X202-2P IRT PRO | All Versions < V5.3 |
| Siemens | SCALANCE X204-2 | All versions < V5.2.5 |
| Siemens | SCALANCE X204-2FM | All versions < V5.2.5 |
| Siemens | SCALANCE X204-2LD | All versions < V5.2.5 |
| Siemens | SCALANCE X204-2LD TS | All versions < V5.2.5 |
| Siemens | SCALANCE X204-2TS | All versions < V5.2.5 |
| Siemens | SCALANCE X204IRT | All Versions < V5.3 |
| Siemens | SCALANCE X204IRT PRO | All Versions < V5.3 |
| Siemens | SCALANCE X206-1 | All versions < V5.2.5 |
| Siemens | SCALANCE X206-1LD | All versions < V5.2.5 |
| Siemens | SCALANCE X208 | All versions < V5.2.5 |
| Siemens | SCALANCE X208PRO | All versions < V5.2.5 |
| Siemens | SCALANCE X212-2 | All versions < V5.2.5 |
| Siemens | SCALANCE X212-2LD | All versions < V5.2.5 |
| Siemens | SCALANCE X216 | All versions < V5.2.5 |
| Siemens | SCALANCE X224 | All versions < V5.2.5 |
| Siemens | SCALANCE X302-7 EEC (230V, coated) | All versions < V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (230V) | All versions < V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (24V, coated) | All versions < V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (24V) | All versions < V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (2x 230V, coated) | All versions < V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (2x 230V) | All versions < V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (2x 24V, coated) | All versions < V4.1.4 |
| Siemens | SCALANCE X302-7 EEC (2x 24V) | All versions < V4.1.4 |
| Siemens | SCALANCE X304-2FE | All versions < V4.1.4 |
| Siemens | SCALANCE X306-1LD FE | All versions < V4.1.4 |
References
Timeline
- Published
- Feb 11, 2020
- Last modified
- Jun 17, 2026
- NVD status
- Modified