CVE-2019-11516

HighCVSS 8.1/10Last modified Jun 17, 2026

Description

An issue was discovered in the Bluetooth component of the Cypress (formerly owned by Broadcom) Wireless IoT codebase. Extended Inquiry Responses (EIRs) are improperly handled, which causes a heap-based buffer overflow during device inquiry. This overflow can be used to overwrite existing functions with arbitrary code. The Reserved for Future Use (RFU) bits are not discarded by eir_handleRx(), and are included in an EIR's length. Therefore, one can exceed the expected 240 bytes, which leads to a heap-based buffer overflow in eir_getReceivedEIR() called by bthci_event_SendInquiryResultEvent(). In order to exploit this bug, an attacker must repeatedly connect to the victim's device in a short amount of time from different source addresses. This will cause the victim's Bluetooth stack to resolve the device names and therefore allocate buffers with attacker-controlled data. Due to the heap corruption, the name will be eventually written to an attacker-controlled location, leading to a write-what-where condition.

Metrics

CVSS 3.1 8.1/10CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Feb 5, 2020
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2019

CVE-2019-115176.5WampServer before 3.1.9 has CSRF in add_vhost.php because the synchronizer pattern implemented as remediation of CVE-2018-8817 was incompletCVE-2019-115187.2An issue was discovered in SEMCMS 3.8. SEMCMS_Inquiry.php allows AID[] SQL Injection because the class.phpmailer.php inject_check_sql protecCVE-2019-115194.9Libraries/Nop.Services/Localization/LocalizationService.cs in nopCommerce through 4.10 allows XXE via the "Configurations -> Languages -> EdCVE-2019-11528.8A remote code execution vulnerability exists when the Windows font library improperly handles specially crafted embedded fonts. An attacker CVE-2019-115218.1OX App Suite 7.10.1 allows Content Spoofing.CVE-2019-115225.4OX App Suite 7.10.0 to 7.10.2 allows XSS.CVE-2019-115239.8Anviz Global M3 Outdoor RFID Access Control executes any command received from any source. No authentication/encryption is done. Attackers cCVE-2019-115269.8An issue was discovered in Softing uaGate SI 1.60.01. A maintenance script, that is executable via sudo, is vulnerable to file path injectioCVE-2019-115278.8An issue was discovered in Softing uaGate SI 1.60.01. A CGI script is vulnerable to command injection with a maliciously crafted url parametCVE-2019-115287.5An issue was discovered in Softing uaGate SI 1.60.01. A system default path for executables is user writable.CVE-2019-11535.5An information disclosure vulnerability exists when the Microsoft Windows Graphics Component improperly handles objects in memory. An attackCVE-2019-115336.1Cross-site scripting (XSS) vulnerability in ProjectSend before r1070 allows remote attackers to inject arbitrary web script or HTML.
CVE-2019-11516: High severity, CVSS 8.1 | Vulnix