CVE-2019-10977

HighCVSS 7.5/10Last modified Jun 17, 2026

Description

In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition.

Metrics

CVSS 3.1 7.5/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
May 23, 2019
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2019

CVE-2019-109787.8Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited whCVE-2019-109799.8SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password.CVE-2019-10986.5An information disclosure vulnerability exists when the Windows GDI component improperly discloses the contents of its memory, aka 'Windows CVE-2019-109807.8A type confusion vulnerability may be exploited when LAquis SCADA 4.3.1.71 processes a specially crafted project file. This may allow an attCVE-2019-109817.8In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local userCVE-2019-109827.8Delta Electronics CNCSoft ScreenEditor, Versions 1.00.89 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by CVE-2019-109837.5In WebAccess/SCADA Versions 8.3.5 and prior, an out-of-bounds read vulnerability is caused by a lack of proper validation of user-supplied dCVE-2019-109847.8Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited whCVE-2019-109859.1In WebAccess/SCADA, Versions 8.3.5 and prior, a path traversal vulnerability is caused by a lack of proper validation of a user-supplied patCVE-2019-109878.8In WebAccess/SCADA Versions 8.3.5 and prior, multiple out-of-bounds write vulnerabilities are caused by a lack of proper validation of the lCVE-2019-109883.4In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 UltrasCVE-2019-109899.8In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation o
CVE-2019-10977: High severity, CVSS 7.5 | Vulnix