CVE-2019-10928

MediumCVSS 6.6/10Last modified Jun 17, 2026

Description

A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device.

Metrics

CVSS 3.1 6.6/10CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Aug 13, 2019
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2019

CVE-2019-109295.9A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variantsCVE-2019-10935.5An information disclosure vulnerability exists when DirectWrite improperly discloses the contents of its memory, aka 'DirectWrite InformatioCVE-2019-109307.5A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet commuCVE-2019-109317.5A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet commuCVE-2019-109336.1A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions <= v3.11), Spectrum Power 4 (Corporate UserCVE-2019-109347.8A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All veCVE-2019-109357.2A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.CVE-2019-109367.5Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker toCVE-2019-109377.5A vulnerability has been identified in SIMATIC TDC CP51M1 (All versions < V1.1.7). An attacker with network access to the device could causeCVE-2019-109389.8A vulnerability has been identified in SIPROTEC 5 devices with CPU variants CP200 (All versions < V7.59), SIPROTEC 5 devices with CPU varianCVE-2019-109399.8A vulnerability has been identified in TIM 3V-IE (incl. SIPLUS NET variants) (All versions < V2.8), TIM 3V-IE Advanced (incl. SIPLUS NET varCVE-2019-10946.5An information disclosure vulnerability exists when the Windows GDI component improperly discloses the contents of its memory, aka 'Windows
CVE-2019-10928: Medium severity, CVSS 6.6 | Vulnix