CVE-2019-0002

CriticalCVSS 9.8/10Last modified Jun 17, 2026

Description

On EX2300 and EX3400 series, stateless firewall filter configuration that uses the action 'policer' in combination with other actions might not take effect. When this issue occurs, the output of the command: show pfe filter hw summary will not show the entry for: RACL group Affected releases are Junos OS on EX2300 and EX3400 series: 15.1X53 versions prior to 15.1X53-D590; 18.1 versions prior to 18.1R3; 18.2 versions prior to 18.2R2. This issue affect both IPv4 and IPv6 firewall filter.

Metrics

CVSS 3.1 9.8/10CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Jan 15, 2019
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2019

CVE-2019-00035.9When a specific BGP flowspec configuration is enabled and upon receipt of a specific matching BGP packet meeting a specific term in the flowCVE-2019-00045.5On Juniper ATP, the API key and the device key are logged in a file readable by authenticated local users. These keys are used for performinCVE-2019-00055.3On EX2300, EX3400, EX4600, QFX3K and QFX5K series, firewall filter configuration cannot perform packet matching on any IPv6 extension headerCVE-2019-00069.8A certain crafted HTTP packet can trigger an uninitialized function pointer deference vulnerability in the Packet Forwarding Engine manager CVE-2019-000710.0The vMX Series software uses a predictable IP ID Sequence Number. This leaves the system as well as clients connecting through the device suCVE-2019-00089.8A certain sequence of valid BGP or IPv6 BFD packets may trigger a stack based buffer overflow in the Junos OS Packet Forwarding Engine managCVE-2019-00095.5On EX2300 and EX3400 series, high disk I/O operations may disrupt the communication between the routing engine (RE) and the packet forwardinCVE-2019-00107.5An SRX Series Service Gateway configured for Unified Threat Management (UTM) may experience a system crash with the error message "mbuf exceCVE-2019-00116.5The Junos OS kernel crashes after processing a specific incoming packet to the out of band management interface (such as fxp0, me0, em0, vmeCVE-2019-00127.5A Denial of Service (DoS) vulnerability in BGP in Juniper Networks Junos OS configured as a VPLS PE allows an attacker to craft a specific BCVE-2019-00137.5The routing protocol daemon (RPD) process will crash and restart when a specific invalid IPv4 PIM Join packet is received. While RPD restartCVE-2019-00147.5On QFX and PTX Series, receipt of a malformed packet for J-Flow sampling might crash the FPC (Flexible PIC Concentrator) process which cause
CVE-2019-0002: Critical severity, CVSS 9.8 | Vulnix