CVE-2018-9078

HighCVSS 8.8/10Last modified Jun 17, 2026

Description

For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the Content Explorer application grants users the ability to upload files to shares and this image was rendered in the browser in the device's origin instead of prompting to download the asset. The application does not prevent the user from uploading SVG images and returns these images within their origin. As a result, malicious users can upload SVG images that contain arbitrary JavaScript that is evaluated when the victim issues a request to download the file.

Metrics

CVSS 3.0 8.8/10CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

No affected versions have been published.

Timeline

Published
Sep 28, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-90799.8For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, adversaries can craft URLs to modify the Document Object CVE-2018-90805.9For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, by setting the Iomega cookie to a known value before loggCVE-2018-90814.7For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the file name used for assets accessible through the ContCVE-2018-90828.8For some Iomega, Lenovo, LenovoEMC NAS devices versions 4.1.402.34662 and earlier, the password changing functionality available to authentiCVE-2018-90838.1In System Management Module (SMM) versions prior to 1.06, the SMM contains weak default root credentials which could be used to log in to thCVE-2018-90846.5In System Management Module (SMM) versions prior to 1.06, if an attacker manages to log in to the device OS, the validation of software updaCVE-2018-90854.9A write protection lock bit was left unset after boot on an older generation of Lenovo and IBM System x servers, potentially allowing an attCVE-2018-90867.2In some Lenovo ThinkServer-branded servers, a command injection vulnerability exists in the BMC firmware download command. This allows a priCVE-2018-90906.1CoreOS Tectonic 1.7.x and 1.8.x before 1.8.7-tectonic.2 deploys the Grafana web application using default credentials (admin/admin) for the CVE-2018-90919.8A critical vulnerability in the KEMP LoadMaster Operating System (LMOS) 6.0.44 through 7.2.41.2 and Long Term Support (LTS) LMOS before 7.1.CVE-2018-90928.8There is a CSRF vulnerability in mc-admin/conf.php in MiniCMS 1.10 that can change the administrator account password.CVE-2018-91016.1A vulnerability in the conferencing component of Mitel MiVoice Connect, versions R1707-PREM SP1 (21.84.5535.0) and earlier, and Mitel ST 14.
CVE-2018-9078: High severity, CVSS 8.8 | Vulnix