CVE-2018-7814

HighCVSS 7.8/10Last modified Jun 17, 2026

Description

A Stack-based Buffer Overflow (CWE-121) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) which could cause remote code to be executed when parsing a GD1 file

Metrics

CVSS 3.0 7.8/10CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

VendorProductVersions
Schneider Electric SEEurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0)Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0)

References

Timeline

Published
Feb 6, 2019
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-78157.8A Type Confusion (CWE-843) vulnerability exists in Eurotherm by Schneider Electric GUIcon V2.0 (Gold Build 683.0) on c3core.dll which could CVE-2018-78166.5A Permissions, Privileges, and Access Control vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that coulCVE-2018-78177.8A Use After Free (CWE-416) vulnerability exists in Zelio Soft 2 v5.1 and prior versions which could cause remote code execution when openingCVE-2018-78209.8A Credentials Management CWE-255 vulnerability exists in the APC UPS Network Management Card 2 AOS v6.5.6, which could cause Remote MonitoriCVE-2018-78217.5An Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmwarCVE-2018-78225.5An Incorrect Default Permissions (CWE-276) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versiCVE-2018-78235.3A Environment (CWE-2) vulnerability exists in SoMachine Basic, all versions, and Modicon M221(all references, all versions prior to firmwareCVE-2018-78244.9An Externally Controlled Reference to a Resource (CWE-610) vulnerability exists in Schneider Electric Modbus Serial Driver (For 64-bit WindoCVE-2018-78258.8A Command Injection vulnerability exists in the web-based GUI of the 1st Gen PelcoSarix Enhanced Camera that could allow a remote attacker tCVE-2018-78268.8A Command Injection vulnerability exists in the web-based GUI of the 1st Gen Pelco Sarix Enhanced Camera that could allow a remote attacker CVE-2018-78275.4A Cross-Site Scripting (XSS) vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera which a remoteCVE-2018-78288.8A Cross-Site Request Forgery (CSRF) vulnerability exists in the 1st Gen. Pelco Sarix Enhanced Camera and Spectra Enhanced PTZ Camera when an
CVE-2018-7814: High severity, CVSS 7.8 | Vulnix