CVE-2018-5465

HighCVSS 8.8/10Last modified Jun 17, 2026

Description

A Session Fixation issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. A session fixation vulnerability in the web interface has been identified, which may allow an attacker to hijack web sessions.

Metrics

CVSS 3.0 8.8/10CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Weakness enumeration

Affected software

VendorProductVersions
n/aHirschmann Automation and Control GmbH Classic Platform SwitchesHirschmann Automation and Control GmbH Classic Platform Switches

References

Timeline

Published
Mar 6, 2018
Last modified
Jun 17, 2026
NVD status
Modified

Related CVEs from 2018

CVE-2018-54667.5Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a self-signed SSL certificate vulnerability this could allow an attacker tCVE-2018-54676.5An Information Exposure Through Query Strings in GET Request issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACHCVE-2018-54689.8Philips Intellispace Portal all versions 7.0.x and 8.0.x have a remote desktop access vulnerability that could allow an attacker to gain unaCVE-2018-54699.8An Improper Restriction of Excessive Authentication Attempts issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACHCVE-2018-54707.8Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an unquoted search path or element vulnerability that has been identified,CVE-2018-54715.9A Cleartext Transmission of Sensitive Information issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, aCVE-2018-54729.8Philips Intellispace Portal all versions 7.0.x and 8.0.x have an insecure windows permissions vulnerability that could allow an attacker to CVE-2018-54739.8An Improper Restriction of Operations within the Bounds of a Memory Buffer issue was discovered in GE D60 Line Distance Relay devices runninCVE-2018-54749.8Philips Intellispace Portal all versions 7.0.x and 8.0.x have an input validation vulnerability that could allow a remote attacker to executCVE-2018-54759.8A Stack-based Buffer Overflow issue was discovered in GE D60 Line Distance Relay devices running firmware Version 7.11 and prior. Multiple sCVE-2018-54767.8A Stack-based Buffer Overflow issue was discovered in Delta Electronics Delta Industrial Automation DOPSoft, Version 4.00.01 or prior. StackCVE-2018-54775.8An Information Exposure issue was discovered in ABB netCADOPS Web Application Version 3.4 and prior, netCADOPS Web Application Version 7.1 a
CVE-2018-5465: High severity, CVSS 8.8 | Vulnix